AI Article Synopsis

  • An analytical method was developed to determine the maximum acceptable grid size for discrete dose calculations in proton therapy, ensuring accurate dose optimization while minimizing unnecessary computational effort.
  • The accuracy requirement stipulates that discrete dose sampling must reconstruct a continuous dose distribution within a 2% error margin, which is influenced by grid size limitations.
  • Utilizing Fourier analysis and the Shannon-Nyquist theorem, the study focused on the behavior of proton beams in water, establishing that the results apply to both infinitesimal pencil beams and finite sized beamlets in intensity modulated proton therapy.

Article Abstract

We developed an analytical method for determining the maximum acceptable grid size for discrete dose calculation in proton therapy treatment plan optimization, so that the accuracy of the optimized dose distribution is guaranteed in the phase of dose sampling and the superfluous computational work is avoided. The accuracy of dose sampling was judged by the criterion that the continuous dose distribution could be reconstructed from the discrete dose within a 2% error limit. To keep the error caused by the discrete dose sampling under a 2% limit, the dose grid size cannot exceed a maximum acceptable value. The method was based on Fourier analysis and the Shannon-Nyquist sampling theorem as an extension of our previous analysis for photon beam intensity modulated radiation therapy [J. F. Dempsey, H. E. Romeijn, J. G. Li, D. A. Low, and J. R. Palta, Med. Phys. 32, 380-388 (2005)]. The proton beam model used for the analysis was a near monoenergetic (of width about 1% the incident energy) and monodirectional infinitesimal (nonintegrated) pencil beam in water medium. By monodirection, we mean that the proton particles are in the same direction before entering the water medium and the various scattering prior to entrance to water is not taken into account. In intensity modulated proton therapy, the elementary intensity modulation entity for proton therapy is either an infinitesimal or finite sized beamlet. Since a finite sized beamlet is the superposition of infinitesimal pencil beams, the result of the maximum acceptable grid size obtained with infinitesimal pencil beam also applies to finite sized beamlet. The analytic Bragg curve function proposed by Bortfeld [T. Bortfeld, Med. Phys. 24, 2024-2033 (1997)] was employed. The lateral profile was approximated by a depth dependent Gaussian distribution. The model included the spreads of the Bragg peak and the lateral profiles due to multiple Coulomb scattering. The dependence of the maximum acceptable dose grid size on the orientation of the beam with respect to the dose grid was also investigated. The maximum acceptable dose grid size depends on the gradient of dose profile and in turn the range of proton beam. In the case that only the phantom scattering was considered and that the beam was aligned with the dose grid, grid sizes from 0.4 to 6.8 mm were required for proton beams with ranges from 2 to 30 cm for 2% error limit at the Bragg peak point. A near linear relation between the maximum acceptable grid size and beam range was observed. For this analysis model, the resolution requirement was not significantly related to the orientation of the beam with respect to the grid.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2241996DOI Listing

Publication Analysis

Top Keywords

maximum acceptable
28
grid size
28
dose grid
20
acceptable grid
16
dose
14
proton beam
12
discrete dose
12
proton therapy
12
dose sampling
12
finite sized
12

Similar Publications

Quality assurance practices performed before treatment are believed to identify various potential errors. In this study, 2-dimensional (2D) dosimetric results were analyzed by making some intentional mistakes in six different treatment plans. In this way, the detectability of errors was investigated.

View Article and Find Full Text PDF

Regulated disinfection byproducts (e.g., trihalomethanes and haloacetic acids) in drinking water networks fluctuate spatially and temporally, depending on water sources and treatment practices with higher concentrations during the summer.

View Article and Find Full Text PDF

Central Pancreatectomy as a Surgical Alternative for Parenchyma Preservation.

Cureus

December 2024

Department of Hepatobiliary and Pancreatic Surgery, Pontificia Universidad Católica de Chile, Santiago, CHL.

Pancreatoduodenectomy and distal pancreatectomy are standard treatments for various pancreatic pathologies. These procedures involve radical resection and a significant loss of pancreatic tissue, which can lead to exocrine and/or endocrine pancreatic insufficiency. In selected cases of benign tumors or those with low malignant potential, central pancreatectomy can be performed with acceptable morbidity and mortality rates.

View Article and Find Full Text PDF

Dietary modification has the potential to improve nutritional status and reduce environmental impacts of the food system. However, for many countries, the optimal composition of locally contextualized healthy and sustainable diets is unknown. The Gambia is vulnerable to climate-change-induced future water scarcity which may affect crop yields and the ability to supply healthy diets.

View Article and Find Full Text PDF

A 25 Year Update on the Facial Nerve Sparing Approach for Vestibular Schwannoma.

World Neurosurg

January 2025

Department of Neurological Surgery, Columbia University Irving Medical Center, New York, NY, USA, 10032; Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY, USA, 10032. Electronic address:

Background And Objectives: This article aims to report results of our facial nerve preservation approach to treating vestibular schwannomas (VS) at a single institution by a single surgeon performing both microsurgery (MS) and stereotactic radiosurgery (SRS).

Methods: We retrospectively reviewed 751 patients at our institution between 1998 and 2023 by intervention received: retrosigmoid microsurgery (MS, Group 1, 217 patients), gamma knife stereotactic radiosurgery (SRS, Group 2, 462 patients), MS then SRS (Group 3, 72 patients), SRS then MS (Group 4, 10 patients), and SRS then SRS (Group 5, 5 patients). No patients had MS followed by MS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!