A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The value of registration correction in the attenuation correction of myocardial SPECT studies using low resolution computed tomography images. | LitMetric

AI Article Synopsis

  • The study investigates how mis-registration between emission and transmission scans affects the interpretation of myocardial perfusion imaging, particularly concerning anterior/apical defects.
  • It found that while attenuation correction reduced the size of inferior wall defects, it often led to an increase in anterior/apical defects, especially in women.
  • Correcting for this mis-registration significantly lowered the incidence of these anterior/apical defects, emphasizing the importance of thorough three-dimensional evaluation before final reports.

Article Abstract

Background: Artifacts caused by tissue attenuation create problems in the interpretation of myocardial perfusion studies. In a previous study we evaluated attenuation correction using 'Hawkeye' and noted that the incidence of anterior/apical defects increased after attenuation correction. This increased incidence appeared to be associated with mis-registration between emission and transmission images. The main aim of this study was to determine whether correction of mis-registration between emission and transmission scans reduced the incidence of these anterior/apical defects.

Methods: Ninety-four patients (64 men, 30 women) underwent stress/rest myocardial perfusion imaging using (99m)Tc-tetrofosmin (188 studies). Bull's-eye perfusion plots were created using proprietary software (QPS).

Results: The marked reduction in defect size, particularly obvious in male patients, in the inferior wall after attenuation correction was not significantly changed by the addition of registration correction. In the anterior and apical walls attenuation correction produced a confusing pattern particularly in females with an overall tendency to increase the defect size. After registration correction fewer anterior/apical defects were created.

Conclusion: Attenuation correction using 'Hawkeye' reduces the incidence of inferior myocardial perfusion defects but can create anterior and/or apical artifacts. It is essential to evaluate registration carefully in three dimensions before reporting the images. Correction of mis-registration reduces the incidence of anterior/apical defects and can restore the appearance of the anterior/apical area to pre-correction levels.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.mnm.0000239483.69027.23DOI Listing

Publication Analysis

Top Keywords

attenuation correction
24
registration correction
12
myocardial perfusion
12
incidence anterior/apical
12
anterior/apical defects
12
correction
10
correction 'hawkeye'
8
mis-registration emission
8
emission transmission
8
correction mis-registration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!