During the last 2 years, some interesting new devices have been made available to improve airway management in children and infants, and several studies have advanced our understanding concerning risks and benefits of the current practice in the field. Certain risk factors for airway related problems during anaesthesia in children having a cold have been identified, and new aspects of the controversy concerning the use of cuffed endotracheal tubes in children presented. Novel video-assisted systems have been introduced for the management of the difficult airway in paediatric patients, and new applications for well known devices have been suggested, such as the laryngeal mask airway serving as guidance for fibreoptic intubation. Recent studies also demonstrated specific problems with the laryngeal mask airway in infants, as well as the advantages of a new prototypic laryngeal mask airway for children, similar to the ProSeal (LMA International S.A. Group, USA). Furthermore, the following review presents new data about the use of the cuffed oropharyngeal airway, the laryngeal tube, and the Arndt bronchus blocker in paediatric patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00001503-200206000-00009 | DOI Listing |
Acta Paediatr
January 2025
Division of Neonatology, Department of Pediatrics, University of Minnesota, Minneapolis, Minnesota, USA.
Am J Transl Res
December 2024
Department of Anesthesiology, Xidian Group Hospital Xi'an 710077, Shaanxi, China.
Objective: To investigate the efficacy of the SaCo videolaryngeal mask airway (VLMA) in combination with a bronchial blocker in patients undergoing minimally invasive thoracoscopic surgery.
Methods: A retrospective analysis was conducted on the clinical data of 120 patients who underwent minimally invasive thoracoscopic surgery from January 2022 to December 2023. Patients were grouped based on their treatment methods: 68 patients who received the SaCo VLMA combined with a bronchial blocker intraoperatively were designated as the L group, while 52 patients who received a tracheal tube combined with a bronchial blocker intraoperatively were designated as the E group.
GMS Hyg Infect Control
December 2024
Uzun Mehmet Chest and Work Diseases Hospital, Medical Microbiology Dept, Zonguldak, Turkey.
Background: The use of laryngeal masks (LM) has increased widely today, both in anesthesia and in emergency cases. LM are available as reusable and disposable. Although reuse of disposable LM is not recommended, they are reused again after decontamination with different methods in anesthesia units in some countries.
View Article and Find Full Text PDFBMJ Open
December 2024
Department of Intensive Care, Cangzhou Central Hospital, Cangzhou, China
Objective: The supraglottic airway device is a viable alternative to tracheal intubation for elective surgery. To conduct a comparative analysis of the advantages and disadvantages associated with use of the Baska mask and I-gel across various dimensions.
Design: A comprehensive search was conducted across PubMed, Embase, Cochrane Library, Web of Science, and other relevant databases to identify randomised controlled trials (RCTs) involving patients who used the Baska mask and I-gel.
Anesth Analg
February 2025
Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.
Background: Several health care networks have fully adopted second-generation supraglottic airway (SGA) i-gel. Real-world evidence of enhanced patient safety after such practice change is lacking. We hypothesized that the implementation of i-gel compared to the previous LMA®-Unique™ would be associated with a lower risk of airway-related safety events.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!