A major limitation in identifying peptides from complex mixtures by shotgun proteomics is the ability of search programs to accurately assign peptide sequences using mass spectrometric fragmentation spectra (MS/MS spectra). Manual analysis is used to assess borderline identifications; however, it is error-prone and time-consuming, and criteria for acceptance or rejection are not well defined. Here we report a Manual Analysis Emulator (MAE) program that evaluates results from search programs by implementing two commonly used criteria: 1) consistency of fragment ion intensities with predicted gas phase chemistry and 2) whether a high proportion of the ion intensity (proportion of ion current (PIC)) in the MS/MS spectra can be derived from the peptide sequence. To evaluate chemical plausibility, MAE utilizes similarity (Sim) scoring against theoretical spectra simulated by MassAnalyzer software (Zhang, Z. (2004) Prediction of low-energy collision-induced dissociation spectra of peptides. Anal. Chem. 76, 3908-3922) using known gas phase chemical mechanisms. The results show that Sim scores provide significantly greater discrimination between correct and incorrect search results than achieved by Sequest XCorr scoring or Mascot Mowse scoring, allowing reliable automated validation of borderline cases. To evaluate PIC, MAE simplifies the DTA text files summarizing the MS/MS spectra and applies heuristic rules to classify the fragment ions. MAE output also provides data mining functions, which are illustrated by using PIC to identify spectral chimeras, where two or more peptide ions were sequenced together, as well as cases where fragmentation chemistry is not well predicted.

Download full-text PDF

Source
http://dx.doi.org/10.1074/mcp.M600320-MCP200DOI Listing

Publication Analysis

Top Keywords

ms/ms spectra
12
search programs
8
manual analysis
8
gas phase
8
proportion ion
8
spectra
6
improved validation
4
peptide
4
validation peptide
4
ms/ms
4

Similar Publications

Advanced lipidomics using UHPLC-ESI-QTOF-MS/MS reveals novel lipids in hibernating syrian hamsters.

J Chromatogr A

January 2025

Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte 28660, España. Electronic address:

Mammalian hibernation offers a unique model for exploring neuroprotective mechanisms relevant to neurodegenerative diseases. In this study, we employed untargeted lipidomics with iterative tandem mass spectrometry (MS/MS) to profile the brain lipidome of Syrian hamsters across different hibernation stages: late torpor, arousal, and euthermia (control). Previously, a lipid species identified as methyl-PA(16:0/0:0) showed a significant increase during torpor, but its precise structure was unresolved due to technological constraints.

View Article and Find Full Text PDF

[Vacuum ultraviolet laser dissociation and proteomic analysis of halogenated peptides].

Se Pu

February 2025

CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.

Chemical modifications are widely used in research fields such as quantitative proteomics and interaction analyses. Chemical-modification targets can be roughly divided into four categories, including those that integrate isotope labels for quantification purposes, probe the structures of proteins through covalent labeling or cross-linking, incorporate labels to improve the ionization or dissociation of characteristic peptides in complex mixtures, and affinity-enrich various poorly abundant protein translational modifications (PTMs). A chemical modification reaction needs to be simple and efficient for use in proteomics analysis, and should be performed without any complicated process for preparing the labeling reagent.

View Article and Find Full Text PDF

Development and Application of a Comprehensive Non-targeted Screening Strategy for Fentanyl Analogues.

J Hazard Mater

January 2025

Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610213, China; Key Laboratory of Monitoring and Assessment on Novel Food Raw Materials, State Administration for Market Regulation, Chengdu 611130, China. Electronic address:

The growing abuse of fentanyl and its analogues (FTNs) presents a substantial public health threat, prompting the introduction of regulatory controls by government authorities. Nevertheless, existing screening strategies for FTNs are primarily based on targeted or non-targeted approaches that utilize a limited set of mass spectrometry fragmentation data, which are far from meeting the needs of class scheduling. In this study, a comprehensive non-targeted screening strategy for FTNs was developed.

View Article and Find Full Text PDF

Targeted and untargeted urinary metabolomics of alkaptonuria patients using ultra high-performance liquid chromatography-tandem mass spectrometry.

J Pharm Biomed Anal

January 2025

Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, Tübingen 72076, Germany. Electronic address:

Alkaptonuria (AKU) is a rare autosomal-recessive disease which is characterized through black urine and ochronosis. It is caused by deficiency of the enzyme Homogentisate 1,2-dioxygenase in the Phenylalanine/Tyrosine degradation pathway which leads to the accumulation of Homogentisic acid (HGA). Urine was provided by AKU patients and healthy controls.

View Article and Find Full Text PDF

Ion Mobility-Assisted Free Radical-Initiated Peptide Sequencing.

Int J Mass Spectrom

February 2025

Department of Chemistry, University of Nevada, 1664 N. Virginia Street, Reno, Nevada 89557, United States.

Free radical-initiated peptide sequencing (FRIPS) is a tandem mass spectrometry technique (MS/MS) that enables radical-based dissociation on instruments only capable of collisional activation. In FRIPS, peptides are chemically-derivatized with a compound that undergoes homolytic cleavage and generates radicals upon collisional activation. These radicals then propagate through the peptide backbone enabling the sequencing of peptide ions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!