Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Intracochlear recordings in cochlear implant recipients provide access to the electrically evoked compound action potential (ECAP). ECAP thresholds are potential predictors of speech processor map's threshold and comfortable loudness levels. The auditory nerve's refractory properties can influence these levels due to high-rate stimulation with interpulse intervals within the relative refractory period. Recovery functions were investigated at 84 stimulation sites in 14 Nucleus CI24 recipients using neural response telemetry and a modified forward masking technique. This technique introduces a reference masker-probe interval (MPI). In our study, an appropriate value between 300 and 375 micro s was determined for this reference MPI, and the use of a reference MPI of 300 micro s is suggested for recovery and amplitude growth functions. A median absolute refractory period of about 390 micro s and a median time constant of about 425 micro s were obtained by fitting an exponential model to the data. Hence, the auditory nerve is usually in relative refractory state when standard neural response telemetry forward masking is selected because of its default MPI of 500 micro s. This can bias the measurement of ECAP thresholds. Additionally, the shape of standard forward masking recovery functions was explained by the influence of latency shift of the neural response.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000095966 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!