Objective: Patients with atrioventricular nodal reentrant tachycardia (AVNRT) could serve as a clinical model to study the effects of mechanical stretch in the electrical properties of atrial myocardium.
Materials And Methods: We studied 14 patients with AVNRT. Peak, mean and minimal atrial pressures, atrial refractoriness (ERP) in the right atrial appendage and high right atrial lateral wall and monophasic action potential duration at 90% of repolarisation (MAPd90) in the right atrial appendage were assessed during atrial pacing at 500 and 400 ms and after 2 min of pacing at the tachycardia cycle length. Measurements were repeated from the same positions after ventricular pacing at the same cycle lengths and after 2 min of tachycardia. Susceptibility to atrial fibrillation (AF) was assessed by noting whether AF was induced during ERP evaluation.
Results: Atrial pressure showed a statistically significant increase during ventricular pacing compared to baseline. This increase remained substantially unchanged when the tachycardia was induced. A significant reduction in atrial ERP and MAPd90 was also observed during ventricular pacing at all cycle lengths compared to atrial pacing. Two minutes of spontaneous tachycardia were enough to change the atrial ERP and MAPd90 to values significantly lower than those during atrial pacing at the cycle length of tachycardia. During the ERP evaluation AF was induced more often during the tachycardia (28%) than during ventricular (14%) and atrial pacing (0%).
Conclusion: In AVNRT patients, ventricular pacing and reentrant tachycardia significantly increase right atrial pressures and subsequently shorten ERP and MAPd90, leading to an enhanced propensity for AF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10840-006-9019-3 | DOI Listing |
Eur Heart J Case Rep
January 2025
Echocardiography Department, Great Ormond Street Hospital for Children, Great Ormond Street, London WC1N 3JH, UK.
Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt.
Case Summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post-endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage.
Pacing Clin Electrophysiol
January 2025
Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Background: This study aimed to compare inappropriate shock (IAS) rates between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (TV-ICD) in Brugada syndrome (BrS) patients and identify risk factors for IAS in S-ICD use.
Methods: We enrolled consecutive patients with BrS who underwent ICD implantation between 2013 and 2023. Data on clinical characteristics, S-ICD screening test data, and IAS occurrence were retrospectively analyzed.
Pacing Clin Electrophysiol
January 2025
Boston Scientific, Corporation: Electrophysiology Research & Development, Arden Hills, Minnesota, USA.
As pulsed-field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!