The modulation frequency dependence of photoacoustic signals obtained from photoactive samples can provide information on the time-dependent enthalpy changes occurring during the light-induced process. The experimental requirements for this type of calorimetry, and the interpretation ot the results, are critically examined with reference to the light-driven proton pump bacteriorhodopsin. For a three-step unbranched model of the bacteriorhodopsin photocycle we derive an expression for the photoacoustic magnitude signal as a function of frequency. Simulations are performed for various values of the rate constants and energetic changes. It is shown that the net heat uptake during a low, final step postulated by some workers should be reflected in the photoacoustic magnitude frequency spectrum, giving rise to a characteristic maximum. However, this effect, which has been observed experimentally, may also be produced by a fast, strongly endothermic step occurring earlier. The precise chronology of an endothermic transition cannot be resolved unambiguously by magnitude measurements alone, although they are free from assumptions regarding difficult-to-measure phase relationships. Hence, the published photoacoustic observations showing the effect are consistent with a cyclic sequence of events in which the bacteriorhodopsin system first undergoes an increase of entropy, followed by a decrease on returning to the initial state, as well as the reverse. It is argued that the molecular disorder-order sequence is more probable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0301-4622(84)87029-5 | DOI Listing |
Photoacoustics
February 2025
Erasmus MC, Cardiovascular Institute, Department of Cardiology, Biomedical Engineering, Rotterdam, The Netherlands.
Photoacoustic imaging offers optical contrast images of human tissue at acoustic resolution, making it valuable for diverse clinical applications. However, quantifying tissue composition via optical contrast remains challenging due to the unknown light fluence within the tissue. Here, we propose a method that leverages known chromophores (, arterial blood) to improve the accuracy of quantitative photoacoustic imaging.
View Article and Find Full Text PDFPhotoacoustics
February 2025
College of Control Science & Engineering, China University of Petroleum (East China), Qingdao 266580, PR China.
Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation.
View Article and Find Full Text PDFPhotoacoustics
February 2025
Dipartimento di Scienze di Base ed Applicate per l'Ingegneria, Sapienza Università di Roma, Rome 00161, Italy.
A compact and robust optical excitation photoacoustic sensor with a self-integrated laser module excitation and an optimized differential resonator was developed to achieve high sensitivity and full linear range detection of carbon dioxide (CO) based on dual modes of wavelength modulated photoacoustic spectroscopy (WMPAS) and resonant frequency tracking (RFT). The integrated laser module equipped with three lasers (a quantum cascade laser (QCL), a distributed feedback laser (DFB) and a He-Ne laser) working in a time-division multiplexing mode was used as an integrated set of spectroscopic sources for detection of the designated concentration levels of CO. With the absorption photoacoustic mode, the WMPAS detection with the QCL and DFB sources was capable of CO detection at concentrations below 20 %, yielding a noise equivalent concentration (NEC) as low as 240 ppt and a normalized noise equivalent absorption coefficient (NNEA) of 4.
View Article and Find Full Text PDFPhotoacoustics
December 2024
Photonics Research Institute, Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR.
Small
December 2024
Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zürich, Winterthurerstrasse 190, Zurich, 8057, Switzerland.
Localization optoacoustic tomography (LOT) has recently emerged as a transformative super-resolution technique breaking through the acoustic diffraction limit in deep-tissue optoacoustic (OA) imaging via individual localization and tracking of particles in the bloodstream. However, strong light absorption in red blood cells has previously restricted per-particle OA detection to relatively large microparticles, ≈5 µm in diameter. Herein, it is demonstrated that submicron-sized porous gold nanoparticles, ≈600 nm in diameter, can be individually detected for noninvasive super-resolution imaging with LOT.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!