A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a sensitive quantification method for hematoporphyrin monomethyl ether in plasma using high-performance liquid chromatography with fluorescence detection. | LitMetric

A rapid, sensitive, precise and specific method for determination of hematoporphyrin monomethyl ether (HMME), a novel photodynamic therapy (PDT) drug, was developed and validated using high-performance liquid chromatography (HPLC) with fluorescence detection. HMME was isolated from the plasma by a single-step liquid-liquid extraction with ethyl acetate. The analyte and internal standard fluorescein were baseline separated on a Diamonsil C(18) analytical column (4.6 x 150 mm, 5 microm) and analyzed using a fluorescence detector with the excitation and emission wavelengths set at 395 and 613 nm, respectively. The method was linear in the concentration range 0.025-5 microg/mL with a lower limit of quantitation (LLOQ) of 10 ng/mL. The inter- and intra-day accuracies and precisions were all within 10% and the mean recoveries of HMME and fluorescein were 95 +/- 3.7 and 90 +/- 2.3%, respectively. The analyte was stable during all sample storage, preparation and analysis periods. This method was successfully applied to a pharmacokinetic study after a single-dose intravenous administration of HMME (5 mg/kg) to beagle dogs. This method was reproducible and sensitive enough for the pharmacokinetic study of HMME. Based on the results of the pharmacokinetic study, we suggest that a rather long light-avoiding time is essential for patients under HMME therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.624DOI Listing

Publication Analysis

Top Keywords

pharmacokinetic study
12
hematoporphyrin monomethyl
8
monomethyl ether
8
high-performance liquid
8
liquid chromatography
8
fluorescence detection
8
hmme
6
method
5
development validation
4
validation sensitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!