Background: The objective of this study was to determine the effects of a moderate exercise training program on functional capacity, quality of life, and hospital readmission rate in chronic heart failure patients with implantable cardioverter defibrillators and cardiac resynchronization therapy.
Methods And Results: We studied 52 men (mean age 55+/-10 years, ejection fraction 31+/-7%) in chronic heart failure II (n=29) and III (n=23) NYHA functional class with ischemic cardiomyopathy who received implantable cardioverter defibrillators with or without cardiac resynchronization therapy. Patients were randomized into two groups. Group T (n=30 patients, 15 implantable cardioverter defibrillator, 15 implantable cardioverter defibrillator+cardiac resynchronization therapy) underwent a supervised exercise training program at 60% of peak VO2 three times a week for 8 weeks. Group C (n=22 patients, 12 implantable cardioverter defibrillator, 10 implantable cardioverter defibrillator+cardiac resynchronization therapy) avoided physical training. At 8 weeks, only trained patients had improvements in peak VO2 (P<0.01 versus C), endothelium-dependent dilatation of the brachial artery (P<0.001 versus C) and quality of life (P<0.001 versus C). Among trained patients, those with cardiac resynchronization therapy had greater improvements in peak VO2 and quality of life. During the follow-up (24+/-6 months), eight controls had sustained ventricular tachycardia requiring hospital readmission, while no trained patients had adverse events (log rank 8.56; P<0.001). The improvement in peak VO2 was correlated with the improvement in endothelium-dependent dilatation (r=0.65).
Conclusion: Moderate exercise training is safe and has beneficial effects after implantable cardioverter defibrillator implantation, especially when cardiac resynchronization therapy is present. These effects are associated with improvement in quality of life and outcome.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.hjr.0000230104.93771.7d | DOI Listing |
Front Cardiovasc Med
December 2024
Department of Paediatrics and Adolescent Medicine, The University of Hong Kong, Pok Fu Lam, Hong Kong SAR, China.
Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.
Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).
Turk J Med Sci
December 2024
Deputy Health Minister, Ministry of Health, Ankara, Turkiye.
Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.
View Article and Find Full Text PDFBMJ Support Palliat Care
December 2024
Wolfson Palliative Care Research Centre, University of Hull, Hull, UK.
Implantable cardioverter defibrillators (ICDs) are implanted in increasing numbers of patients with the aim of treating ventricular arrhythmias in high-risk patients and reducing their risk of dying. Individuals are also living longer with these devices. As a result, a greater number of patients with an ICD will deteriorate either with worsening cardiac failure, another non-cardiac condition or general frailty and will have a limited prognosis.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany.
Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.
Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.
Results: The majority of patients (87.
J Cardiovasc Dev Dis
December 2024
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary.
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!