Background: Catheter-restricted antibiotic lock solutions were found to be effective in the prevention of catheter-related bacteremia (CRB), but insufficient data are available about the ideal agent and dose. We hypothesized that a low concentration of gentamicin would be as effective as the high doses studied in the past.

Methods: In this prospective, open-labeled, randomized, clinical trial of patients on long-term hemodialysis therapy, patients were randomly assigned to administration of an antibiotic lock solution of gentamicin/citrate (4 mg/mL), minocycline/EDTA, or the control solution of heparin. Patients were followed up until the study end point of CRB was reached or a censoring event occurred. Interim data analysis was performed after 6 months to assess data safety; efficacy was noted and the study was terminated early.

Results: Sixty-two patients were enrolled into the study, evenly distributed in 3 arms, with data from 1 patient excluded from analysis. Seven of 20 patients in the heparin group (4.0 events/1,000 catheter days), 1 of 21 patients in the minocycline group (0.4 events/1,000 catheter days), and none of 20 patients in the gentamicin group developed bacteremia. Results were statistically significant by using 2-tailed Fisher exact test; heparin versus gentamicin, P = 0.008, and heparin versus minocycline, P = 0.020.

Conclusion: Antibiotic lock solutions are superior to the standard heparin lock alone in the prevention of CRBs, and low-dose gentamicin solution has efficacy similar to that of greater concentrations used in previous studies.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.ajkd.2006.06.012DOI Listing

Publication Analysis

Top Keywords

lock solutions
12
antibiotic lock
12
low-dose gentamicin
8
prevention catheter-related
8
catheter-related bacteremia
8
group events/1000
8
events/1000 catheter
8
catheter days
8
days patients
8
heparin versus
8

Similar Publications

Background: Bleeding and thrombotic occlusion are complications of Central venous catheters. When selecting a catheter lock solution, factors such as bleeding, thrombotic occlusion, infection, and cost-effectiveness must be considered.

Methods: The study included 35 patients who used heparin as a locking solution and 35 patients who used 0.

View Article and Find Full Text PDF

Purpose: To implement and evaluate the feasibility of brain spin-lattice relaxation in the rotating frame (T1ρ) mapping using a novel optimized pulse sequence that incorporates weighted spin-lock acquisitions, enabling high-resolution three-dimensional (3D) mapping.

Methods: The optimized variable flip-angle framework, previously proposed for knee T1ρ mapping, was enhanced by integrating weighted spin-lock acquisitions. This strategic combination significantly boosts signal-to-noise ratio (SNR) while reducing data acquisition time, facilitating high-resolution 3D-T1ρ mapping of the brain.

View Article and Find Full Text PDF

Physics-guided multi-dimensional scan optimization and quasi-steady-state reconstruction to enhance CEST MRI sensitivity efficiency and quantification accuracy.

J Magn Reson

December 2024

Non-Human-Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States; Winship Cancer Institute, Emory University School of Medicine, Atlanta, GA, United States. Electronic address:

Chemical exchange saturation transfer (CEST) MRI has become increasingly utilized for detecting dilute labile protons and characterizing microenvironment properties. However, the CEST MRI effect is only a few percent, and there is a need for a systematic approach to optimize scan parameters for sensitive and accurate CEST quantification. We propose multi-dimensional adjustments of key parameters such as the repetition time (TR) and RF duty cycle to optimize CEST MRI sensitivity per unit of time and utilization of quasi-steady-state (QUASS) reconstruction to recover the full CEST effect during postprocessing.

View Article and Find Full Text PDF

A heterodyne laser Doppler vibrometer (LDV) with a Bragg cell has a stationary signal carrier at a frequency of at least 35 MHz. The expensive Bragg cell with the restricted shift frequency is not an optimal solution to meet the requirements for many measurement scenarios. For vibrations with low frequencies and small amplitudes, a tens-of-megahertz carrier frequency not only wastes bandwidth at the photodetector but also requires a fast and expensive analog-to-digital converter (ADC).

View Article and Find Full Text PDF

Periodic external driving of transmission-delay-coupled phase oscillator system: Switching between different twisted states.

Chaos

December 2024

Research Group for Nonlinear Dynamics, Department of Physics, University of Science, Unjong-District, Pyongyang, Democratic People's Republic of Korea.

We consider the effects of an external periodic forcing on a spatially extended system that consists of identical phase oscillators coupled with transmission delays on a ring. Analyzing the continuum limit N→∞ of the model system along the Ott-Antonsen invariant manifold, we obtain the stability diagram for two regimes, called the forced and drifting entrainments. The former exhibits a spatially homogeneous solution trying to lock onto the drive, of which the stability boundary is rigorously determined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!