Background: Video capsule endoscopy (VCE) may be useful for surveillance of small-bowel polyps in patients with familial adenomatous polyposis (FAP).

Objective: To compare VCE to standard endoscopy for diagnosing small-bowel polyps in a defined segment of small bowel (proximal to a tattoo) and the entire examined small bowel.

Design: Prospective.

Setting: Single tertiary referral center.

Patients: Participants with FAP (n = 32). The majority were selected for their high number of proximal small-bowel polyps and prior endoscopic tattoo placement in the proximal small bowel.

Interventions: VCE (interpreted by 2 readers), push enteroscopy (PE), and lower endoscopy (LE) to count and measure small-bowel polyps.

Results: In the defined segment, VCE detected a median of 10.0 (interquartile range [IQR], 5.0-19.0) and 9.0 (IQR, 6.0-16.0) polyps for each reader compared with a median of 41.0 (IQR, 19.0-64.0) polyps on PE (P = .002). Agreement between the 2 methods was fair (kappa = 0.34, 0.36). Agreement between VCE and PE was poor to fair (kappa = 0.10, 0.22) for estimating the size of the largest polyp and poor (kappa = -0.20, -0.27) for detecting large polyps (> or =1 cm). In the entire examined small bowel, VCE diagnosed a median of 38.0 (IQR, 10.5-71.5) and 54.0 (IQR, 13.0-100.0) polyps for each reader compared with a median of 123.0 (IQR, 38.5-183.0) for combination endoscopy (PE and LE) (P < .001). Agreement between the 2 methods was fair to moderate (kappa = 0.21, 0.56).

Limitations: Participants selected for high polyp burden, and results may not be applicable to all patients with FAP.

Conclusions: VCE underestimates the number of small-bowel polyps in persons with FAP and does not reliably detect large polyps.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2005.12.014DOI Listing

Publication Analysis

Top Keywords

small-bowel polyps
20
polyps
10
video capsule
8
capsule endoscopy
8
standard endoscopy
8
polyps persons
8
familial adenomatous
8
adenomatous polyposis
8
defined segment
8
small bowel
8

Similar Publications

Prosthetic joint infection (PJI), caused by Streptococcus bovis group (SBG), is uncommon and related to colorectal cancer. We present here a case of an 84-year-old male who had a past medical history of chronic obstructive pulmonary disease (COPD), congestive heart failure, pulmonary arterial hypertension, iron deficiency anemia, chronic kidney disease, diabetes mellitus, gout, hypertension, bilateral knee replacement with left knee pain and swelling. We initially suspected gout and treated him with prednisolone, but it did not relieve him.

View Article and Find Full Text PDF

The ileocecal valve in transabdominal ultrasound. Part 2: Pathological lesions.

J Ultrason

December 2024

Department of Diagnostic Imaging and Interventional Radiology, Pomeranian Medical University, Szczecin, Poland.

The aim of this paper is to present our experience in transabdominal ultrasonography of ileocecal valve lesions. The ileocecal valve, located in the central part of the ileocecal bowel segment, is rarely the primary site of disease processes. It is usually involved by pathologies in adjacent bowel segments.

View Article and Find Full Text PDF
Article Synopsis
  • Adult intussusception (AI) is a rare condition in patients over 18 that presents with various symptoms, often requiring surgical treatment, and is primarily diagnosed using CT scans.
  • A study of 26 cases revealed that the condition is more common in males with an average age of 53, where the most frequent symptom is abdominal pain; however, bleeding per rectum is notably linked to more severe, malignant causes.
  • Understanding the characteristics and predictive factors of AI can help in managing the condition effectively, emphasizing the importance of a multidisciplinary approach in treatment strategies.
View Article and Find Full Text PDF
Article Synopsis
  • - Small bowel intussusception in adults is rare and can be caused by small bowel polyps.
  • - This case report discusses an adult patient who experienced jejunojejunal intussusception due to a large polyp in the jejunum.
  • - The polyp served as the lead point for the intussusception, illustrating a specific cause of this condition in adults.
View Article and Find Full Text PDF
Article Synopsis
  • This study investigated the effectiveness of terminal ileal intubation (TII) during routine colonoscopies, focusing on whether it improves the detection of lesions.
  • A retrospective analysis of 13,372 patients revealed no significant differences in polyp detection rates or lesion detection rates between those who had TII and those who did not.
  • The results concluded that TII is unnecessary in routine colonoscopies due to its limited diagnostic value and lack of benefit in detecting lesions.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!