Screening for colorectal neoplasia with CT colonography: initial experience from the 1st year of coverage by third-party payers.

Radiology

Department of Radiology and Section of Gastroenterology and Hepatology, University of Wisconsin Medical School, E3/311 Clinical Science Center, 600 Highland Ave, Madison, WI 53792-3252, USA.

Published: November 2006

Purpose: To evaluate our experience in the 1st year of computed tomographic (CT) colonography screening since the initiation of local third-party payer coverage.

Materials And Methods: This HIPAA-compliant study was approved by the institutional review board, and informed consent was waived. Over a 1-year period that ended on April 27, 2005, 1110 consecutive adults (585 women, 525 men; mean age, 58.1 years) underwent primary CT colonography screening. More than 99% were covered by managed care agreements. CT colonographic interpretation was performed with primary three-dimensional polyp detection, and the final results were issued within 2 hours. Patients with large (> or =10-mm) polyps were referred for same-day optical colonoscopy, and patients with medium-sized (6-9-mm) lesions had the option of immediate optical colonoscopy or short-term CT colonography surveillance.

Results: Large colorectal polyps were identified at CT colonography in 43 (3.9%) of 1110 patients. Medium-sized lesions were identified in 77 (6.9%) patients, 31 (40%) of whom chose optical colonoscopy and 46 (60%) of whom chose CT colonography surveillance. Concordant lesions were identified in 65 of 71 patients who underwent subsequent optical colonoscopy (positive predictive value, 91.5%). Sixty-one (86%) of 71 optical colonoscopic procedures were performed on the same day as CT colonography, thereby avoiding the need for repeat bowel preparation. The actual endoscopic referral rate for positive findings at CT colonography was 6.4% (71 of 1110 patients). The demand for CT colonography screening from primary care physicians and their patients increased throughout the study period.

Conclusion: As a primary colorectal screening tool, CT colonography covered by third-party payers has an acceptably low endoscopic referral rate and a high concordance of positive findings at optical colonoscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2412052007DOI Listing

Publication Analysis

Top Keywords

optical colonoscopy
20
colonography screening
12
colonography
10
experience 1st
8
1st year
8
third-party payers
8
patients medium-sized
8
1110 patients
8
lesions identified
8
endoscopic referral
8

Similar Publications

Colorectal cancer is one of the most prevalent forms of cancer globally. The most common routine diagnostic methods are the examination of the interior of the colon during colonoscopy or sigmoidoscopy, which frequently includes the removal of a biopsy sample. Optical methods, such as Raman spectroscopy (RS) and optical coherence tomography (OCT), can help to improve diagnostics and reduce the number of unnecessary biopsies.

View Article and Find Full Text PDF

Colonoscopies are vital procedures allowing diagnosis of colorectal cancer and other gastrointestinal diseases. However, excessive forces may be applied to the colon during navigation. This can cause bleeding, especially in patients presenting inflammatory bowel diseases.

View Article and Find Full Text PDF

Background: Despite adequate treatment, a subgroup of patients with inflammatory bowel disease (IBD), including Crohn`s disease and ulcerative colitis, have persistent gastrointestinal symptoms that are not always related to mucosal damage. Recently, two autoantibodies, anti-CdtB and anti-vinculin, were validated as post-infectious IBS (PI-IBS) markers, however there is limited evidence of its diagnostic role in IBD population.

Methods: Patients with more than 3 bowel movements/day and indication of colonoscopy were enrolled.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the need for an objective method to evaluate and compare different computer-aided detection (CADe) algorithms used in colorectal cancer screening, as their performance varies and no standard exists.
  • A modified Delphi approach was employed, where 25 experts generated and prioritized scoring criteria over eight months, ultimately identifying six key metrics, including sensitivity and adenoma detection rate.
  • The resulting criteria aim to guide the development and improvement of CADe software, with future research suggested to validate these metrics on benchmark video datasets.
View Article and Find Full Text PDF

Purpose: To evaluate the presence of congenital hypertrophy of the retinal pigment epithelium in a large family affected by familial adenomatous polyposis and identify the causative mutation in the adenomatous polyposis coli gene. Thus, we aimed to determine the significance of congenital hypertrophy of the retinal pigment epithelium as a phenotypic marker of the disease.

Methods: A family consisting of 95 individuals was evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!