A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy. | LitMetric

This paper offers a realistic review of kilovoltage X-ray cone beam tomography integrated with the treatment machine for image-guided radiotherapy in the light of experience taking a commercial system from prototype development into clinical use. It shows that key practicalities cannot be ignored, in particular the regular characterization of mechanical flex during gantry rotation, the mapping of defects in flat panel image transducers and their response to X-ray exposure. The number of X-ray projections and the doses required for clinically useful cone beam reconstruction at different therapy sites are considered in the context of imaging that is fit for purpose. Three roles for cone beam tomography in radiotherapy are identified: patient setup in three dimensions (3D), where even low dose cone beam tissue detail is superior to megavoltage imaging; disease targeting where, despite wide field scatter and slow scanning, it is possible to generate images that are suitable for tumour delineation even at challenging sites; adaptive treatment planning, where calibrated cone beam images have been shown to provide sufficient target detail to support "plan of the day" selection and have the potential for planning with bulk corrections. With frequent use in mind, the need to limit patient dose during setup, yet maximize much needed image quality in the target zone, is considered. Finally, it is noted that the development of cone beam tomography for radiotherapy is far from complete, with X-ray source, image transducer, reconstruction algorithms and techniques for image profile collection still being researched.

Download full-text PDF

Source
http://dx.doi.org/10.1259/bjr/68255935DOI Listing

Publication Analysis

Top Keywords

cone beam
28
beam tomography
12
kilovoltage x-ray
8
x-ray cone
8
image-guided radiotherapy
8
tomography radiotherapy
8
cone
7
beam
7
x-ray
5
developments experience
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!