Rationale And Objectives: Diagnostic mammography is performed on women with clinical symptoms that suggest breast cancer or women for whom further mammographic evaluation has been requested because of an abnormal screening mammography. We assessed whether the use of full-field digital mammography would improve the positive predictive value (PPV) for the diagnosis of breast cancer in a diagnostic population compared with film-screen mammography.
Materials And Methods: From January 2002 to December 2003, 11,621 patients underwent diagnostic mammography at the University of North Carolina Hospital, Chapel Hill. Among these 11,621 patients, 1400 lesions in 1121 patients underwent biopsy. We included the biopsy-performed lesions, so PPV3 was used for comparison of PPVs between film-screen mammography and full-field digital mammography. Six breast radiologists interpreted the images using the Breast Imaging Reporting and Data System of the American College of Radiology. PPV3s were compared between film-screen and full-field digital mammography in the entire study cohort and in specified subgroups according to different radiologists, breast density, and lesion type on mammography. The chi(2) and Fisher's exact tests were used for comparison of PPV3s between two modalities of mammography with the Bonferroni procedure for subgroup analysis.
Results: In the entire study cohort, PPV3s of full-field digital mammography and film-screen mammography were similar (difference in PPV3,-0.007; 95% confidence interval, -0.081 to 0.068; P = .8602). In predefined subgroups, there was no difference in PPV3 by the radiologist, breast density, or lesion type between two modalities of mammography (P > .005).
Conclusion: There is no improvement in PPV for the diagnosis of breast cancer with full-field digital mammography compared with film-screen mammography in a large diagnostic population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acra.2006.07.007 | DOI Listing |
Phys Med
January 2025
National Co-ordinating Centre for the Physics of Mammography (NCCPM), Medical Physics Department, Royal Surrey NHS Foundation Trust, Guildford GU2 7XX UK.
Background: The American Association of Physicists in Medicine (AAPM) Task group 282 (TG282) in collaboration with the European Federation for Organisations of Medical Physics (EFOMP) have developed a novel breast dosimetry model intended as a single international standard.
Purpose: To explore the impact of TG282 dosimetry on estimates of average Mean Glandular Dose (MGD) in the United Kingdom (UK) National Health Service (NHS) Breast Screening Programmes (BSP).
Methods: MGDs were estimated, using the TG282 dosimetry model, for the most recent UK NHSBSP dose survey.
AJR Am J Roentgenol
January 2025
Department of Radiology, Division of Breast Imaging and Intervention, Mayo Clinic, Phoenix, AZ.
Contrast-enhanced mammography (CEM) is growing in clinical use due to its increased sensitivity and specificity compared to full-field digital mammography (FFDM) and/or digital breast tomosynthesis (DBT), particularly in patients with dense breasts. To perform an intraindividual comparison of MGD between FFDM, DBT, a combination protocol using both FFDM and DBT (combined FFDM-DBT), and CEM, in patients undergoing breast cancer screening. This retrospective study included 389 women (median age, 57.
View Article and Find Full Text PDFACS Biomater Sci Eng
January 2025
Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, Massachusetts 01609, United States.
Mechanical properties of engineered connective tissues are critical for their success, yet modern sensors that measure physical qualities of tissues for quality control are invasive and destructive. The goal of this work was to develop a noncontact, nondestructive method to measure mechanical attributes of engineered skin substitutes during production without disturbing the sterile culture packaging. We optimized a digital holographic vibrometry (DHV) system to measure the mechanical behavior of Apligraf living cellular skin substitute through the clear packaging in multiple conditions: resting on solid agar as when the tissue is shipped, on liquid media in which it is grown, and freely suspended in air as occurs when the media is removed for feeding.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electrical Engineering, Chinese Culture University, Taipei 11114, Taiwan.
This paper presents an effective three-dimensional (3D) surface reconstruction technique aimed at profiling composite surfaces with both specular and diffuse reflectance. Three-dimensional measurements based on fringe projection techniques perform well on diffuse reflective surfaces; however, when the measurement targets contain both specular and diffuse components, the efficiency of fringe projection decreases. To address this issue, the proposed technique integrates digital holography into the fringe projection setup, enabling the simultaneous capture of both specular and diffuse reflected light in the same optical path for full-field surface profilometry.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Urban Construction College, Wuchang Shouyi University, Wuhan 430064, China.
This research advocates for the use of basalt fiber-reinforced polymer (BFRP) bars and recycled tire steel fibers to reinforce concrete beams. Six concrete beams were constructed using different volume contents of recycled tire steel fibers (0, 0.5%, 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!