A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of rapid streptococcal antigen testing varies by personnel. | LitMetric

Performance of rapid streptococcal antigen testing varies by personnel.

J Clin Microbiol

Department of Pediatrics, Division of Emergency Medicine, Children's Hospital of Akron, Akron, Ohio 44308, USA.

Published: November 2006

Rapid carbohydrate antigen tests are frequently used to diagnose group A streptococcal (GAS) pharyngitis. Despite evidence of modest sensitivity in medical settings, rapid antigen tests are available to the public for self-testing. We sought to determine if the personnel performing a rapid streptococcal antigen test influence the test's performance characteristics. Throat swabs of pediatric patients performed for GAS pharyngitis in a tertiary-care children's hospital network were included during two study periods in 2004 and 2005. The performance characteristics of a rapid carbohydrate antigen test were evaluated in three clinical settings against a nucleic acid probe test method according to the personnel performing the test (laboratory technologist versus nonlaboratory personnel). Between the study periods, nonlaboratory personnel from one site underwent retraining. Subsequently, the performance characteristics of the rapid antigen test were reassessed. The sensitivity of the rapid antigen test varied widely among the different testing sites (56 to 90%). Notably, test sensitivity was consistently greater when the test was performed by laboratory technologists than when it was performed by nonlaboratory personnel (P < 0.0001). Although the rapid antigen test sensitivity significantly improved after nonlaboratory personnel at one testing site were retrained (sensitivity before versus after retraining; P < 0.0001), the sensitivity remained greater in the laboratory technologist cohort (P < 0.0001). These data confirm the important relationship of the operator performing a rapid streptococcal antigen test with the test's accuracy, even in a clinical setting, where operator training is mandated. Therefore, its use outside the medical setting by lay persons cannot be recommended without culture backup.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1698329PMC
http://dx.doi.org/10.1128/JCM.01399-06DOI Listing

Publication Analysis

Top Keywords

antigen test
24
rapid antigen
16
nonlaboratory personnel
16
rapid streptococcal
12
streptococcal antigen
12
performance characteristics
12
test
10
antigen
9
rapid
8
rapid carbohydrate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!