Background: We performed a pilot study examining the feasibility of a new unprepped CT colonography (CTC) strategy: low fiber diet and tagging (unprepped) vs. low fiber diet, tagging and a magnesium citrate cleansing preparation (prepped). Prior reports of tagging were limited in that the residual stool was neither measured and stratified by size nor did prior reports subjectively evaluate the ease of interpretation by a reader experienced in interpreting CTC examinations.
Methods: Prospective randomized to unprepped n = 14 and prepped n = 14. Colonic segments were subjectively evaluated for residual stool that would potentially interfere with interpretation. Scores were given in the following categories: percentage of residual stool that was touching or nearly touching mucosa, the largest piece of retained stool, effectiveness of tagging, height of residual fluid, degree of distention, ease of interpretation, and reading time.
Results: Ease of the CT read (scale where 4 = optimal read) averaged 1.3 for the unprepped group and 2.3 for the prepped group. The mean read time averaged 17.5 min for unprepped and 17.9 min for prepped. The degree of distention (scale where 4 = well distended) averaged 3.7 for unprepped and 3.6 for prepped. Supine and prone images combined, the unprepped group had 160 segments with stool; prepped group had 58 segments. The amount of stool covering the mucosa in all segments averaged 1.6 (33%-66% coverage) in the unprepped group and 0.35 (<33% mucosal coverage) in the prepped group. The mean size of the largest piece of stool was 33.67 mm for unprepped and 4.01 mm for prepped. Percentage of tagged stool was not significantly different between the groups (range of 94-98%). The height of residual fluid averaged 8.37 mm for unprepped and 13.4 mm for prepped. Three polyps in three patients were found during optical colonoscopy (OC) in the unprepped group (5, 6, and 10 mm), none of which were prospectively detected at CTC. Three polyps in three patients were detected during OC in the prepped group (5, 10, and 15 mm), two of which were prospectively detected at CTC. Two false-positive lesions were observed at CTC in one patient in the prepped group.
Conclusion: There was more stool in the unprepped group and while this factor did not slow down the reading time, it made the examination subjectively harder to interpret and likely caused the three polyps in this group to be missed. We conclude that a truly unprepped strategy that leaves significant residual stool, even if well tagged, is not desirable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00261-006-9044-9 | DOI Listing |
World J Urol
January 2025
Department of Urology, Azienda Socio Sanitaria Territoriale Lariana, Como, Italy.
Purpose: To compare the effect on sexual function of ejaculation-sparing enucleation of the prostate using Thulium: YAG laser (ES-ThuLEP) versus continuous-wave Thulium Fiber Laser (ES-ThuFLEP).
Methods: 112 patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia who wished to preserve ejaculation were treated. 58 patients underwent ES-ThuLEP (Group A) using the Cyber TM generator.
ACS Sustain Resour Manag
January 2025
Sandia National Laboratories, Albuquerque, New Mexico 87123, United States.
Wind energy offers a low emission source of energy while also being among the cheapest forms of electricity generation in the United States. While most materials in a wind turbine can be recycled at the end of their life, large composite blades are often treated as waste, leading to potential strains on regional landfills, a loss of durable materials, and forfeiture of embodied energy. Numerous approaches exist for recycling composite wind blades at various levels of technological and commercial maturity.
View Article and Find Full Text PDFAs a low-energy method to increase the data rate of optical links in data centers, we propose self-homodyne Nyquist optical time division multiplexing (OTDM). In Nyquist OTDM, spectrally efficient high-baud rate signals can be generated exceeding the limit of electronic signal processing. However, full integration of OTDM systems has not been reported, mainly because of the complicated signal detection scheme, which involves demultiplexing and clock recovery.
View Article and Find Full Text PDFWe demonstrate a widely spaced, stabilized, and self-referenced opto-electronic oscillator driven electro-optic modulator based optical frequency comb. Using an ultra-stable Fabry-Perot etalon as a stable reference, we simultaneously stabilize a CW laser and generate a low noise and stable RF oscillation used to drive an electro-optic comb. In such a manner, the Fabry-Perot etalon pins both the carrier-envelope-offset frequency ( ) and the repetition rate of the comb in place ( ), eliminating the need for an external RF oscillator.
View Article and Find Full Text PDFAdvancements in plasmonic sensing require simultaneous detection capability that ensures large-scale detection with reduced losses. In this work, we propose a new solid-core fiber-based refractive index (RI) sensor with an ultra-broad detection range. The proposed fiber consists of a relatively simple single-ring cladding with six circular tubes in which the light is guided in the core based on the inhibited-coupling (IC) mechanism.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!