Error analysis for rotating active Stokes-Mueller imaging polarimeters.

Opt Lett

Université Louis Pasteur, Laboratoire des Sciences de l'Image et de la Télédétection CNRS UMR 7005, Illkirch, France.

Published: October 2006

Retrieval of Mueller matrices from intensity measurements is a noise-sensitive process. In addition, the choice of the method used for extracting Mueller matrix elements greatly influences the precision of the final results. Among available procedures, three have been tested and their robustness analyzed by adding Gaussian noise to computer synthesized data and have been verified by comparing experimental data. As expected, the methods based on classical matrix inversion reach their noise reduction limit even if more data are considered. In contrast, the discrete Fourier transform approach features a remarkable stability. The identified reason is that the retrieval process corresponds to filtering with a periodic kernel.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.31.002858DOI Listing

Publication Analysis

Top Keywords

error analysis
4
analysis rotating
4
rotating active
4
active stokes-mueller
4
stokes-mueller imaging
4
imaging polarimeters
4
polarimeters retrieval
4
retrieval mueller
4
mueller matrices
4
matrices intensity
4

Similar Publications

A prediction model for electrical strength of gaseous medium based on molecular reactivity descriptors and machine learning method.

J Mol Model

January 2025

Hubei Key Laboratory·for High-Efficiency-Utilization of Solar Energy and Operation, Control of Energy-Storage System, Hubei-University of Technology, Wuhan, 430068, China.

Context: Ionization and adsorption in gas discharge are similar to electrophilic and nucleophilic reactions. The molecular descriptors characterizing reactions such as electrostatic potential descriptors are useful in predicting the electrical strength of environmentally friendly gases. In this study, descriptors of 73 molecules are employed for correlation analysis with electrical strength.

View Article and Find Full Text PDF

Background: Meniscal surgery is one of the most frequent orthopaedic procedures performed worldwide. There is a wide range of possible treatment errors that can occur following meniscal surgery. In Norway, patients subject to treatment errors by hospitals and private institutions can file a compensation claim free of charge to the Norwegian System of Patient Injury Compensation (NPE).

View Article and Find Full Text PDF

Background: Effective diagnostic capacity is crucial for clinical decision-making, with up to 70% of decisions in high-resource settings based on laboratory test results. However, in low- and middle-income countries (LMIC) access to diagnostic services is often limited due to the absence of Laboratory Information Management Systems (LIMS). LIMS streamline laboratory operations by automating sample handling, analysis, and reporting, leading to improved quality and faster results.

View Article and Find Full Text PDF

Complex structures can be understood as compositions of smaller, more basic elements. The characterization of these structures requires an analysis of their constituents and their spatial configuration. Examples can be found in systems as diverse as galaxies, alloys, living tissues, cells, and even nanoparticles.

View Article and Find Full Text PDF

Highly sensitive split ring resonator-based sensor for quality monitoring of edible oils.

Sci Rep

January 2025

Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (UKM), 43600, Bangi, Selangor, Malaysia.

This research presents the design and analysis of a compact metamaterial (MTM)-based star-shaped split-ring resonator (SRR) enclosed in a square, constructed on a cost-effective substrate for liquid chemical sensing applications. The designed structure has dimensions of 10 × 10 mm and is optimized for detecting adulteration in edible oils. When the sample holder is filled with different percentages of oil samples, the resonance frequency of the MTM-based SRR sensor shift significantly.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!