We reviewed the performance of a new polymethylpentene oxygenator (DIDECMO, Dideco, Mirandola, Italy) in terms of clinical safety and efficiency in priming, oxygenation, and oxygenator resistance in neonatal and pediatric extracorporeal membrane oxygenation (ECMO) patients. Between March 2005 and January 2006, 14 patients required ECMO in the San Vincenzo Hospital. Of these, 8 (median age, 9 days; range, 3 days to 15 months) received normothermic ECMO for postcardiotomy heart failure after surgery for congenital heart disease. The DIDECMO oxygenator was used in all patients (median weight, 2.4 kg; range, 2 to 7 kg). According to our previous experience, all patients received the same anticoagulation management. DIDECMO is a new phosphorylcholine-coated, polymethylpentene hollow-fiber oxygenator recommended for a maximum blood flow of 2300 ml/min with a membrane surface area of 0.67 m2 and validated to be used up to 5 days. Static priming was 100 ml and mean support time 05 hours (range, 36 to 198 hours). No oxygenators were changed during support. Median pressure drop during overall assistance was 24 mm Hg. Carbon dioxide elimination was obtained with a 1:1 blood flow/air flow ratio. Neither oxygenator-related major nor minor adverse events occurred during support. In our initial experience, the new polymethylpentene DIDECMO oxygenator provided adequate gas exchange and offered technical advantages in terms of low priming volume and acceptable hemodynamic resistance despite pulsatile flow regimen. Also, we used this device for more than 8 days without any technical problems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.mat.0000237693.09432.13 | DOI Listing |
J Artif Organs
January 2025
Department for Cardiac, Thoracic and Cardiovascular Surgery, University Hospital Regensburg, Regensburg, Germany.
Neutrophil extracellular traps (NETs) were detected in blood samples and in cellular deposits of oxygenator membranes during extracorporeal membrane oxygenation (ECMO) therapy and may be responsible for thrombogenesis. The aim was to evaluate the effect of the base material of gas fiber (GF, polymethylpentene) and heat exchange (HE) membranes and different antithrombogenic coatings on isolated granulocytes from healthy volunteers under static culture conditions. Contact of granulocytes with membranes from different ECMO oxygenators (with different surface coatings) and uncoated-GFs allowed detection of adherent cells and NETotic nuclear structures (normal, swollen, ruptured) using nuclear staining.
View Article and Find Full Text PDFJ Artif Organs
August 2024
Professor Emeritus of Chemical Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-Ku, Tokyo, 169-8555, Japan.
Since the COVID-19 pandemic of 2020-2023, extracorporeal membrane oxygenator (ECMO) has attracted considerable attention worldwide. It is expected that ECMO with long-term durability is put into practical use in order to prepare for next emerging infectious diseases and to facilitate manufacturing for novel medical devices. Polypropylene (PP) and polymethylpentene (PMP) capillary membranes are currently the mainstream for gas exchange membrane for ECMO.
View Article and Find Full Text PDFPerfusion
August 2024
Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
Introduction: Polymethylpentene (PMP) oxygenators serve as the primary oxygenator type utilized for ECMO. With the number of PMP oxygenators available, it has become increasingly important to determine differences among each oxygenator type that can lead to varying metrics of oxygenator dysfunction.
Methods: This study was a retrospective, single-center analysis of adult patients supported on ECMO between December 2020 to December 2021 with varying PMP oxygenators including the Medtronic Nautilus Smart (Minneapolis, MA), the Eurosets AMG PMP (Medolla, Italy) and Getinge Quadrox-iD and the Getinge Cardiohelp HLS Module Advanced System (Gothenberg, Sweden).
Micromachines (Basel)
July 2024
Department of Smart Sensors and Microsystems, SINTEF Digital, Gaustadalléen 23C, 0373 Oslo, Norway.
With the rapid development and commercial interest in the organ-on-a-chip (OoC) field, there is a need for materials addressing key experimental demands and enabling both prototyping and large-scale production. Here, we utilized the gas-permeable, thermoplastic material polymethylpentene (PMP). Three methods were tested to prototype transparent PMP films suitable for transmission light microscopy: hot-press molding, extrusion, and polishing of a commercial, hazy extruded film.
View Article and Find Full Text PDFBMC Pulm Med
January 2024
Critical care resident, Universidad de La Sabana, Chía, Colombia.
Background: The SARS-CoV-2 pandemic resulted in shortages of supplies, which limited the use of extracorporeal membrane oxygenation (ECMO) support. As a contingency strategy, polypropylene (PP) oxygenation membranes were used. This study describes the clinical outcomes in patients on ECMO with PP compared to poly-methylpentene (PMP) oxygenation membranes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!