Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: This study is situated in the area of measuring set-up accuracy and time periods of single-session extracranial radiotherapy (SSRT) for simple-shaped targets (e.g., spherical or rotational symmetrical) definitively located in the peripheral lung.
Methods And Materials: After adaptation of the stereotactic body frame, the patient has to remain in the vacuum pillow during planning computed tomography (CT), fast three-dimensional (3-D) treatment planning, and direct irradiation after verification. Fast preplanning is performed by using virtual simulation software to accelerate the method.
Results: In our new procedure, SSRT is applied in approximately 1.5 h. The mean setup accuracy vector was 2.4+/-0.7 mm in the range of 1.34 to 4 mm. Mean intrafractional patient movement in the stereotactic body frame before and after radiation was 0.70 mm+/-0.5 mm and 0.76+/-0.76 mm in the range of 0 to 2.8 mm. Mean time period steps were measured at (1) planning CT with 3-D treatment planning: 76+/-12 min; (2) irradiation and verification: 33+/-7 min; and (3) complete procedure duration: 109+/-11 min (range, 89-169).
Conclusions: The main difference between the positioning technique of SSRT and that of conventional extracranial radiosurgery is the tighter patient fixation, which guarantees minimal patient movement. The main advantages are procedure acceleration and omission of CT simulation. SSRT is a preliminary stage of real-time treatment.