Process-scale antibody production requires polishing steps with extremely high product throughput and robust operation. In this communication, the Sartobind Q membrane adsorber for process-scale antibody production is evaluated as an alternative to Q column chromatography. Although the capacity seen with large-scale membrane adsorbers is competitive with column chromatography, the same throughput is not achieved with the current scale-down models. The operational issues currently found in membrane scale-down models, including backpressure, which significantly compromises the membrane's capacity, were examined. A new scale-down model was designed to mimic the liquid flow path found in the large-scale capsule, and a new process capacity equivalent at both small and large scale was successfully achieved. Results of a 4-model virus study with a redesigned Sartobind Q absorber scale-down model at the new process capacity are presented.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2006.08.064DOI Listing

Publication Analysis

Top Keywords

scale-down model
12
process-scale antibody
12
membrane scale-down
8
antibody production
8
column chromatography
8
scale-down models
8
process capacity
8
membrane
4
model process-scale
4
antibody purification
4