Purpose: To investigate the impact of rectum motion on dose - volume histograms of the rectum including filling and of the wall (DVH and DWH, respectively), during 3D-conformal radiotherapy (3DCRT) for localized prostate cancer.
Materials And Methods: Ten patients received a planning CT scan (CT(0)) and 11-14 CT during 3DCRT for prostate cancer (total CT scans=126). CT images were 3D matched using bony anatomy. A single observer drew the external contours of rectum and rectum wall and the CTV (prostate + seminal vesicles) on CT(0). Patients were asked to empty their rectum before every CT, as generally performed at the Institute for Cancer Research and Treatment (IRCC) before treatment delivery. Bladder was kept full by drinking 500 cm(3) of water 60 min before the scan, according to our protocol. A 4-field box 3DCRT technique was planned and dose statistics/dose - volume histograms of the rectum were calculated for each contour referred to CT(0),CT(1),...,CT(n) for each patient. Average DVHs during treatment were calculated along with their standard deviation (SD(rand)) and compared to the planned DVH. The analyses on the patient population included the assessment of systematic deviation (average difference and SD, named SD(sys)) as well as the average SD(rand) value expressing the random component of organ motion. Rectum shifts were also assessed by anterior and lateral BEV projections.
Results: As to the rectum, 8/10 patients showed a "better" average DVH than DVH on CT(0). Wilcoxon test showed a statistically significant reduction when correlating the difference Delta between the average DVH during therapy and planning DVH at CT(0): for instance V(70)Delta = -3.6% and p = 0.022, V(50)Delta = -5.5% and p = 0.022, D(med)Delta = -3.2 Gy and p = 0.007. Average values of DVH systematic difference (average difference between planning scan and treatment), standard deviations (SD(sys)) and average standard deviations of the random fluctuation (SD(random)) were -4.0%, 4.7% and 6.6%, respectively. Whilst the fluctuation results were slightly smaller for DWH. Volume analysis showed a slight systematic variation of the rectal volume between planning and treatment BEV. The average rectal volume during therapy was larger than at the planning CT in 8/10 patients. The systematic shifts of the rectal wall between the planning phase and the treatment were rather small, both below and above the flexure. The larger random fluctuation of the rectum shape was found to be in the cranial half (1 SD=4.4 mm).
Conclusions: The practice of carefully emptying the rectum during simulation and therapy for prostate cancer, which is a safe and simple procedure, reduces the impact of organ motion on dose - volume parameters of the rectum.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.radonc.2006.08.007 | DOI Listing |
Brain Res Bull
January 2025
Department of Animal Biology, School of Biology, College of Science, University of Tehran, Tehran, Iran.
The present study investigated the impact of GABAergic signaling and miRNA expression on glioblastoma multiforme (GBM) growth within the medial prefrontal cortex (mPFC) and its associated cognitive and emotional impairments. The implantation of C6 cells into the mPFC induced GBM in this brain region (referred to as the mPFC-GBM) in male Wistar rats via stereotaxic surgery, as confirmed by Magnetic Resonance Imaging (MRI), and Hematoxylin and Eosin (H&E) staining. Repeated microinjections of muscimol, a potent GABA receptor agonist, directly into the mPFC-GBM (1µg/rat/2.
View Article and Find Full Text PDFSci Rep
January 2025
Radiation Safety and Quality Assurance division, National Cancer Center Hospital East, Chiba, 277-8577, Japan.
The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.
View Article and Find Full Text PDFSci Rep
January 2025
Instituto do Coração (InCor), Faculdade de Medicina, Hospital das Clínicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
Doxorubicin-induced cardiomyopathy (DOX-IC) is a significant and common complication in patients undergoing chemotherapy, leading to cardiac remodeling and reduced heart function. We hypothesized that the intrapericardial injection of hydrogels derived from the cardiac decellularized extracellular matrix (dECM) loaded with adipose tissue-derived stromal cells (ASC) and their secretome dampens or reverses the progression of DOX-IC. DOX-IC was induced in Wistar male rats through ten weekly intra-peritoneal injections of doxorubicin (cumulative dose: 18 mg/kg).
View Article and Find Full Text PDFPhys Med Biol
January 2025
Radiotherapy and Radiosurgery department, Iatropolis Clinic, 54 Ethnikis Antistaseos ave., Athens, Attica, 15231, GREECE.
Using the concept of biologically effective dose (BED), the effect of sublethal DNA damage repair (SLR) on the bio-efficacy of prolonged radiotherapy treatments can be quantified (BED). Such treatments, lasting more than 20 min, are typically encountered in stereotactic radiosurgery (SRS) applications using the CyberKnife (CK) and Gamma knife systems. Evaluating the plan data from 45 Vestibular Schwannoma (VS) cases treated with single fraction CK-SRS, this work demonstrates a statistically significant correlation between the marginal BEDSLR delivered to the target (m-BEDSLR) and the ratio of the mean collimator size weighted by the fraction of total beams delivered with each collimator ((_w^m)Cs), to the tumor volume (Tv).
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Department of Radiology, Ulsan University Hospital, Ulsan, Republic of Korea (T.Y.L.); Department of Radiology, University of Ulsan College of Medicine, Seoul, Republic of Korea (T.Y.L.); Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea (J.H.Y., H.K., J.M.L.); Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea (J.H.Y., S.H.P., J.M.L.); Department of Radiology, Inje University Busan Paik Hospital, Busan, Republic of Korea (J.Y.P.); Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea (S.H.P.); Department of Radiology, Hanyang University College of Medicine, Seoul, Republic of Korea (C.L.); Division of Biostatistics, Medical Research Collaborating Center, Seoul National University Hospital, Seoul, Republic of Korea (Y.C.); and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea (J.M.L.).
Objective: The aim of this study was to intraindividually compare the conspicuity of focal liver lesions (FLLs) between low- and ultra-low-dose computed tomography (CT) with deep learning reconstruction (DLR) and standard-dose CT with model-based iterative reconstruction (MBIR) from a single CT using dual-split scan in patients with suspected liver metastasis via a noninferiority design.
Materials And Methods: This prospective study enrolled participants who met the eligibility criteria at 2 tertiary hospitals in South Korea from June 2022 to January 2023. The criteria included (a) being aged between 20 and 85 years and (b) having suspected or known liver metastases.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!