A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Artifact of indicators equipped to stereotactic body frame scanned by 16-row MDCT can be resolved]. | LitMetric

We found an artifact of the Stereotactic Body Frame's (SBF) indicators when we used diagnostic 16-row multi-detector computed tomography (MDCT) as a simulator. Stereotactic radiotherapy (SRT) requires the accuracy of each millimeter. However, a gap of 3 mm at the maximum along the Z axis was caused by this artifact. We assessed the characteristics and cause of this artifact and searched for an imaging parameter to reduce the artifact in SRT. It was considered that the artifact was formed mainly by a stair-step artifact and cone-beam artifact. We can acquired accuracy, 1 mm minimizing the beam width and pitch (10 mm/0.5625). However, exposure time was extended because minimum pitch was selected. The influence on dose calculation was negligible. We decided to use a default parameter for treatment planning, and this parameter for determining the isocenter. We found the MDCT parameters to get acceptable positional accuracy for SRT with SBF.

Download full-text PDF

Source
http://dx.doi.org/10.6009/jjrt.62.1127DOI Listing

Publication Analysis

Top Keywords

stereotactic body
8
artifact
7
[artifact indicators
4
indicators equipped
4
equipped stereotactic
4
body frame
4
frame scanned
4
scanned 16-row
4
16-row mdct
4
mdct resolved]
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!