A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stimulated jitter in the masseter muscle: normative values. | LitMetric

Stimulated jitter in the masseter muscle: normative values.

Muscle Nerve

Department of Neurology, Ibn Sina Hospital, PO Box 25427, Safat, 13115, Kuwait.

Published: February 2007

Nineteen healthy volunteers (median age, 25; range, 18-51 years) were enrolled in a study to obtain normative values for stimulated jitter in the masseter muscle. Axonal microstimulation was performed via a monopolar needle electrode introduced in the masseter 2-2.5 cm above the mandibular angle on the line connecting it with the lateral canthus. The recording single-fiber electromyography (SFEMG) electrode was inserted anteriorly in the twitching area of the muscle. The mean consecutive difference (MCD) values for the 426 endplates studied followed a distribution skewed to the left, with a minimum value of 4.3 micros, maximal 44.7 micros, and a maximum of distribution at 11 micros. Mean pooled MCD measured 16.0 micros, and the mean of mean MCD per study was 13.6 micros. The value of the 95th upper percentile for an individual fiber was 29.3 micros. We suggest an upper normal limit for mean MCD per study of 21 micros and upper normal limit of MCD for individual fibers of 30 micros. The stimulated jitter study of masseter muscle is easy and reliable.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mus.20651DOI Listing

Publication Analysis

Top Keywords

stimulated jitter
12
masseter muscle
12
jitter masseter
8
normative values
8
micros
8
mcd study
8
micros upper
8
upper normal
8
normal limit
8
limit mcd
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!