Background: Several minimally invasive saphenous vein harvesting techniques have been developed to reduce morbidities associated with coronary artery bypass grafting. This prospective, randomized study was designed to compare two commonly used minimally invasive saphenous vein harvesting techniques, the SaphLITE Retractor System (Teleflex Medical) and the Clearglide Endoscopic Vessel Harvesting System (Ethicon CardioVations, Inc.).

Methods: Between January 2003 and March 2004, a total of 200 patients scheduled for primary, nonemergent coronary artery bypass grafting, with or without concomitant procedures were randomized into two groups: SaphLITE (n = 100) and Clearglide (n = 100). Pre-, intra- and postoperative data was collected and subjected to statistical analysis. Randomization provided homogenous groups with respect to preoperative risk factors.

Results: Harvest location for the SaphLITE group was thigh (n = 40), lower leg (n = 5) and both lower leg and thigh (n = 55). The location of harvest for the Clearglide group was thigh (n = 3), lower leg (n = 16) and both lower leg and thigh (n = 81). The mean incision length was 3.6 cm (range, 2-6) in the SaphLITE group versus 2.1 cm (range, 1-4) in the Clearglide group (p < 0.05). The total incision length was 12.9 cm versus 8.9 (p < 0.05) in the SaphLITE and Clearglide groups. Conversion to the open technique occurred in 5 SaphLITE patients and 7 Clearglide patients. Intraoperative leg exploration for bleeding occurred in two of the Clearglide patients and none of the SaphLITE patients. Post-operative complications specifically related to minimally invasive harvesting technique, including a two-week post-discharge visit, were not statistically different between the groups.

Conclusion: The saphenous vein can be safely harvested utilizing the SaphLITE and Clearglide systems. While the Clearglide system allows for fewer incisions (number and length) and less harvest time, these benefits may be outweighed by the increased cost of the Clearglide system compared to the SaphLITE retractor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1579211PMC
http://dx.doi.org/10.1186/1749-8090-1-24DOI Listing

Publication Analysis

Top Keywords

lower leg
16
saphlite retractor
12
minimally invasive
12
saphenous vein
12
clearglide
11
saphlite
10
prospective randomized
8
randomized study
8
teleflex medical
8
ethicon cardiovations
8

Similar Publications

Objectives: To compare lag-screw slide and revision surgery rate between two generations of the Stryker Gamma cephalomedullary nail (Stryker, Kalamazoo, MI).

Methods: Design: Retrospective chart review.

Setting: Single academic, Level-1 Trauma Center.

View Article and Find Full Text PDF

Practitioners of medicine have a moral as well as legal obligation to serve their patients to the best of their ability, and in recent years the medical profession throughout the world has affirmed this principle. But where there is negligence of this sacred duty, a claim arises. Most civil claims are governed by the law of limitation, which restricts the time in which a plaintiff can bring a suit.

View Article and Find Full Text PDF

: The aim of this study is to determine whether different playing positions in football influence muscle asymmetry, which is a common cause of injuries in football. This study aimed to determine the difference in the functional and lateral asymmetry of the knee joint muscles measured using tensiomyography (TMG) between football players of different playing positions. : This study included 52 professional football players (25.

View Article and Find Full Text PDF

Theoretically, animals with longer hindlimbs are better jumpers, while those with shorter hindlimbs are better maneuverers. Yet experimental evidence of this relationship in mammals is lacking. We compared jump force and maneuverability in a lab population of Mongolian gerbils (Meriones unguiculatus).

View Article and Find Full Text PDF

Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!