Background: Left ventricular aneurysm (LVA) may affect diastolic intraventricular blood flow. Color M-mode (CMM) Doppler flow propagation patterns are abnormal in the presence of apical aneurysms. The aim of this study was to validate the accuracy of CMM echocardiography for assessing the existence and size of LVA and to determine the intraventricular pressure gradient in LVA.
Methods: CMM of the transmitral inflow in early diastole was obtained from the apical 4-chamber view in 19 sheep. The presence of the break point where the velocity decreased abruptly in the mitral inflow (point D) was determined and the distance between the apex and point D was measured. The intraventricular pressure difference between the base and the apex was measured by a catheter while it was calculated using CMM with the Euler equation.
Results: The presence of the break point D showed 84% sensitivity and 100% specificity for determining the existence of an LVA. Distance between the apex and point D correlated well with scar size. Catheter- and CMM-derived intraventricular pressure difference correlated and agreed well (y = 1.0 x -0.2, r = 0.94).
Conclusions: The point of abrupt decrease in propagation velocity of the CMM recording indicated the presence and size of LVA. Intraventricular pressure gradients were determined noninvasively by CMM echocardiography with reasonable accuracy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2006.04.015 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
University Medical Center Göttingen, Department of Cardiology and Pneumology, Georg-August University, Robert-Koch-Str. 40, 37099, Göttingen, Germany.
Background: Pulmonary stenosis (PS) is common in congenital heart disease and an integral finding in Tetralogy of Fallot (TOF). Pulmonary regurgitation (PR) is more commonly found following surgery in repaired TOF. We aimed to evaluate the haemodynamic effects of PS and PR on cardiac physiology in a porcine model using cardiac magnetic resonance-based feature tracking (CMR-FT) deformation imaging.
View Article and Find Full Text PDFJ Physiol Sci
January 2025
Department of Hematology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-Ku, 252-0374, Sagamihara, Kanagawa, Japan.
Mean circulatory filling pressure, venous return curve, and Guyton's graphical analysis are basic concepts in cardiovascular physiology. However, some medical students may not know how to view and interpret or understand them adequately. To deepen students' understanding of the graphical analysis, in place of having to perform live animal experiments, we developed an interactive cardiovascular simulator, as a self-learning tool, as a web application.
View Article and Find Full Text PDFOpen Heart
January 2025
Department of Cardiothoracic and Vascular Surgery, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Aims: Exercise testing remains underused in patients with aortic stenosis (AS), partly due to concerns about an exercise-induced drop in systolic blood pressure (SBP). We aimed to study the SBP response to exercise in patients with severe symptomatic AS prior to surgery and 1 year postoperatively.
Methods: Patients scheduled for aortic valve replacement due to severe symptomatic AS were enrolled at a single centre in a prospective observational cohort study.
Br J Pharmacol
January 2025
Laboratory of Veterinary Pharmacology, School of Veterinary Medicine, Kitasato University, Towada, Japan.
Background And Purpose: Eukaryotic elongation factor 2 kinase (eEF2K) belongs to the Ca/calmodulin-dependent protein kinase family. We previously revealed that A484954, a selective eEF2K inhibitor, caused hypotensive and diuretic effects via the production of nitric oxide (NO) in spontaneously hypertensive rats. Otsuka Long-Evans Tokushima Fatty (OLETF) rats are hypertensive because of obesity and type 2 diabetes.
View Article and Find Full Text PDFJ Clin Neurosci
January 2025
Department of Ultrasonic Medicine, Fudan University Affiliated Huashan Hospital, No 12, Middle Wulumuqi Road, Shanghai 200040, China. Electronic address:
Objective: This prospective observational study aimed to assess the effectiveness of B-mode ultrasound, color-coded Doppler, and shear-wave elastography in predicting intracranial pressure (ICP) and their capability to evaluate the efficacy of ICP lowering therapy.
Materials And Methods: Forty-eight neuro-critical care patients were enrolled and categorized into 2 groups based on ICP measurements obtained through external ventricular drainage: the intracranial hypertension (IH) and normal ICP groups. The optic nerve (ON) sheath diameter (ONSD), end diastolic velocity, peak systolic velocity, resistance index of the central retinal artery (CRA), and Young's modulus (YM) of the ON were recorded after external ventricular drainage placement and following ICP lowering treatment in the IH group.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!