AI Article Synopsis

  • A rapid LC/ESI-MS/MS method was developed to accurately measure isosorbide-5-mononitrate (5-ISMN) in human plasma, essential for treating angina pectoris.
  • The procedure includes solid-phase extraction and reversed-phase liquid chromatography, ensuring a high recovery rate of the analyte with minimal matrix effect.
  • With a quick analysis time of 2 minutes, the method demonstrated excellent precision and accuracy in various test conditions, making it effective for bioequivalence studies.

Article Abstract

A rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the determination of isosorbide-5-mononitrate (5-ISMN), used in the treatment of angina pectoris, in human plasma is described. The quantification of 5-ISMN was performed via stable acetate adduct formation with a high relative abundance. The plasma filtrate obtained after solid-phase extraction (SPE), using a polymer based, hydrophilic-lipophilic balanced (HLB) cartridge, was submitted directly to reversed-phase high-performance liquid chromatography separation followed by ESI and detection of the resulting ions using triple-quadrupole mass spectrometry in selected reaction monitoring (SRM) mode. There was no significant matrix effect on the analysis. For validation of the method, the recovery of the free analyte response was compared to that obtained from an optimized extraction method. The analyte stability was examined under conditions mimicking the sample storage, handling, and analytical procedures. The extraction procedure yielded extremely clean extracts with a recovery of 95.51% and 93.98% for iossorbide-5-mononitrate and topiramate (internal standard (IS)), respectively. The calibration curves were linear for the dynamic range of 10.0 to 1000.0 ng/mL with a correlation coefficient r > or = 0.9985. The intra-assay and inter-assay precision for the samples at the lower limit of quantification (LLOQ) were 9.02 and 13.30%, respectively. The intra-assay accuracies at LLOQ, LQC, MQC and HQC levels varied from 98.13 to 118.15, 102.34 to 105.21, 100.69 to 109.68, and 95.76 to 102.92%, respectively, while the inter-assay accuracies ranged from 93.10 to 118.15, 93.03 to 107.04, 86.97 to 109.68 and 86.18 to 105.85%, respectively, at these levels. The method is rugged and fast with a total run time of 2 min. The method was successfully applied for a bioequivalence study in 24 human subject samples after oral administration of 60 mg extended release (ER) formulations.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.2684DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
human plasma
8
liquid chromatography/electrospray
8
chromatography/electrospray ionization
8
ionization tandem
8
tandem mass
8
method
5
extensive study
4
study isosorbide-5-mononitrate
4
isosorbide-5-mononitrate acid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!