Percutaneous devices play an essential role in medicine; however, they are often associated with a significant risk of infection. One approach to circumvent infection would be to heal the wound around the devices by promoting skin cell attachment. We used two in vitro assay models to evaluate cutaneous response to poly(2-hydoxyethyl methacrylate) (poly(HEMA)). One approach was to use a cell adhesion assay to test the effects of surface modification of poly(HEMA), and the second used an organ culture system of newborn foreskin biopsies implanted with porous poly(HEMA) rods (20 microm pores) to evaluate the skin/poly(HEMA) interface. Surface modification of poly(HEMA) using 1,1'-carbonyldiimidazole (CDI) enhanced keratinocyte, fibroblast, and endothelial cell adhesion. Keratinocytes in the organ culture model not only remained functionally and structurally viable as observed by immunohistochemistry and electron microscopy, but migrated into the pores of CDI-modified poly(HEMA) rods. No biointegration was seen in the non-CDI-modified poly(HEMA). Laminin 5 immunostaining was seen along the poly(HEMA)/skin interface in a pattern resembling the junctional epithelium of the tooth, the unique natural interface between the skin and tooth that serves as a barrier to bacteria. In vitro systematic evaluation of biomaterials for use in animal implant studies is both cost effective and time efficient.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1743-6109.2006.00138.xDOI Listing

Publication Analysis

Top Keywords

interface skin
8
cell adhesion
8
surface modification
8
modification polyhema
8
organ culture
8
polyhema rods
8
polyhema
6
characterization vitro
4
vitro model
4
model evaluating
4

Similar Publications

Skin-like bioelectronics offer a transformative technological frontier, catering to continuous and real-time yet highly imperceptible and socially discreet digital healthcare. The key technological breakthrough enabling these innovations stems from advancements in novel material synthesis, with unparalleled possibilities such as conformability, miniature footprint, and elasticity. However, existing solutions still lack desirable properties like self-adhesivity, breathability, biodegradability, transparency, and fail to offer a streamlined and scalable fabrication process.

View Article and Find Full Text PDF

Dual-Response UV Radiation Detector Based on Color Switching and Photoresistance Response for UV Radiation Monitoring.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of New Energy and Rare Earth Resource Utilization of State Ethnic Affairs Commission, Key Laboratory of Photosensitive Materials & Devices of Liaoning Province, School of Physics and Materials Engineering, Dalian Minzu University, Dalian 116600, People's Republic of China.

Ultraviolet (UV) irradiation is dangerous and can cause serious skin diseases if skin is excessively exposed to it. Thus, it is highly desirable for human health to monitor the UV radiation intensity. In this report, a flexible and stretchable dual-response UV radiation detector is reported by integrating UV-responsive color-switchable WO quantum dots (QDs) with an electrical hydrogel.

View Article and Find Full Text PDF

Structural insights into isoform-specific RAS-PI3Kα interactions and the role of RAS in PI3Kα activation.

Nat Commun

January 2025

NCI RAS Initiative, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Frederick, MD, USA.

Mutations in RAS and PI3Kα are major drivers of human cancer. Their interaction plays a crucial role in activating PI3Kα and amplifying the PI3K-AKT-mTOR pathway. Disrupting RAS-PI3Kα interaction enhances survival in lung and skin cancer models and reduces tumor growth and angiogenesis, although the structural details of this interaction remain unclear.

View Article and Find Full Text PDF

This is a retrospective cross-sectional diagnostic test accuracy study of direct immunofluorescence (DIF) performed on a group of potential lupus erythematosus (LE)/dermatomyositis (DM) skin biopsies from 2015 to 2020 at a large, academic medical center. For purposes of this study, which was focused primarily on detection of LE/DM-related interface dermatitis, DIF was considered positive for a LE/DM pattern if it showed granular deposition of immunoglobulin G, with or without C3, at the basement membrane zone on the final pathology report. Blinded clinicopathologic correlation was the reference standard.

View Article and Find Full Text PDF

Evaluating interface pressure in a lower-limb prosthetic socket: Comparison of FEM and experimental measurements on a roll-over simulator.

J Biomech

January 2025

Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, 151 boulevard de l'Hôpital, 75013 Paris, France. Electronic address:

Improper socket fitting in lower-limb prostheses can lead to significant complications, including pain, skin lesions, and pressure ulcers. Current suspension and socket design practices rely predominantly on visual inspection of the residual limb and patient feedback. Monitoring stress distribution at the residual limb/socket interface offers a more objective approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!