Galvanoforming for large-span fixed restorations in the treatment of periodontally compromised patients.

Int J Periodontics Restorative Dent

Department of Prosthodontics and Periodontology, School of Dental Medicine, Medical University of Graz, Graz, Austria.

Published: August 2006

Large-span fixed restorations in the treatment of periodontally compromised patients are technically difficult to realize. Despite existing techniques of regenerative periodontal surgery and implant therapy aimed at preventing large spans by increasing the number of abutments, prosthetic complications do occur. The present article describes a method that introduces galvanic caps to conventional prosthetic technology, which facilitates clinical procedures and reduces complications by improving precision of fit.

Download full-text PDF

Source

Publication Analysis

Top Keywords

large-span fixed
8
fixed restorations
8
restorations treatment
8
treatment periodontally
8
periodontally compromised
8
compromised patients
8
galvanoforming large-span
4
patients large-span
4
patients technically
4
technically difficult
4

Similar Publications

The rapid advancement of mobile laser scanner technology used for terrain mapping, among other things, imposes increasing requirements for scanning frequency and distance measurement accuracy. To meet these requirements, rangefinder modules are expected to operate with high echo signal dynamics and to allow accurate distance measurement even based on single-laser-pulse echo detection. Such performance can be potentially achieved using pulsed time-of-flight (ToF) laser rangefinders (LRF).

View Article and Find Full Text PDF

New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Biomed Res Int

April 2022

Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Innovations in digital manufacturing enabled the fabrication of implant-supported fixed dental prostheses (ISFDPs) in a wide variety of recently introduced materials. Computer-aided design and computer-aided manufacturing (CAD-CAM) milling allows the fabrication of ISFDPs with high accuracy by reducing the fabrication steps of large-span frameworks. The longevity of ISFDPs depends on the overall mechanical properties of the framework material including its fit, and the physical properties of the veneering material and its bond with the framework.

View Article and Find Full Text PDF

[Pure titanium denture large-span frameworks additively manufactured with selective laser melting].

Zhonghua Kou Qiang Yi Xue Za Zhi

July 2021

Nanjing Qianzhi Intelligent Technology Limited Company, Nanjing 211111, China.

To investigate the accuracy of pure titanium and cobalt-chromium alloy frameworks fabricated using the additive manufacturing (AM) of selective laser melting technology (SLM) for the mandibular implant-supported fixed prostheses and the maxillary removable partial denture (RPD), and to provide a reference for clinical application of SLM pure titanium frameworks. One edentulous mandibular model with implants and screw fixed abutments at bilateral canines and the first molars was selected and used as the mandibular full arch implant-supported model. At the same time, a Kennedy class Ⅰ maxillary dentition defect model was selected.

View Article and Find Full Text PDF

Purpose: To synthesize a zirconia-toughened alumina (ZTA) composite with 85% alumina matrix reinforced by 15% zirconia and to characterize its optical and mechanical properties before and after artificial aging, to be compared with a conventional dental zirconia (3Y-TZP).

Material And Methods: After syntheses, ZTA and 3Y-TZP powders were uniaxially and isostatically pressed. Green-body samples were sintered and polished to obtain 80 disc-shaped specimens per group (12 × 1 mm, ISO 6872:2015).

View Article and Find Full Text PDF

Beating the Standard Sensitivity-Bandwidth Limit of Cavity-Enhanced Interferometers with Internal Squeezed-Light Generation.

Phys Rev Lett

April 2017

Institut für Laserphysik und Zentrum für Optische Quantentechnologien, Universität Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany.

The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intracavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!