A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of level and frequency on the audibility of partials in inharmonic complex tones. | LitMetric

Effects of level and frequency on the audibility of partials in inharmonic complex tones.

J Acoust Soc Am

Department of Experimental Psychology, University of Cambridge, Downing Street, Cambridge CB2 3EB, England.

Published: August 2006

The effect of level and frequency on the audibility of partials was measured for complex tones with partials uniformly spaced on an equivalent rectangular bandwidth (ERB(N)) number scale. On each trial, subjects heard a sinusoidal "probe" followed by a complex tone. The probe was mistuned downwards or upwards (at random) by 4.5% from the frequency of one randomly selected partial in the complex. The subject indicated whether the probe was higher or lower in frequency than the nearest partial in the complex. The frequencies were roved from trial to trial, keeping frequency ratios fixed. In experiment 1, the level per partial, L, was 40 or 70 dB SPL and the mean frequency of the central partial, f(c), was 1201 Hz. Scores for the highest and lowest partials in the complexes were generally high for all spacings. Scores for the inner partials were close to chance at 0.75-ERB(N) spacing, and improved as the spacing was increased up to 2 ERB(N). For intermediate spacings, performance was better for the lower level used. In experiment 2, L was 70 dB SPL and f(c) was 3544 Hz. Performance worsened markedly for partial frequencies above 3544 Hz, consistent with a role of phase locking.

Download full-text PDF

Source
http://dx.doi.org/10.1121/1.2216906DOI Listing

Publication Analysis

Top Keywords

level frequency
8
frequency audibility
8
audibility partials
8
complex tones
8
partial complex
8
frequency
6
partials
5
complex
5
partial
5
effects level
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!