The use of cardiac pacing to deal with bradycardia is well established. There is debate as to the benefits during cardiopulmonary resuscitation (CPR). This study was performed to compare the effects of transoesophageal cardiac pacing and high-dose epinephrine on the benefits of cardiopulmonary resuscitation after asphyxial cardiac arrest in rats. Thirty Sprague-Dawley rats of both sexes were randomly selected to a saline group (Sal-gro, treated with normal saline 1 mL IV, n = 10), an epinephrine group (Epi-gro, treated with epinephrine 0.4 mg/kg IV, n = 10), or a pacing group (Pac-gro, treated with normal saline 1 mL IV combined with transoesophageal cardiac pacing, n = 10) in a blinded fashion during resuscitation after 10 minutes of asphyxial cardiac arrest. Manual chest compression was in all cases performed using the same methodology by the same personnel who was blinded to hemodynamic monitor tracings. The rate of restoration of spontaneous circulation was 1 (10%), 7 (70%), and 8 (80%) of 10 in Sal-gro, Epi-gro, and Pac-gro, respectively. The rate of ventilator withdrawal within 60 minutes after resuscitation in Pac-gro was higher than that of Epi-gro (8/8 vs 1/7, respectively; P = .001); the survival rate after 2 hours in Pac-gro was significantly higher than that in Epi-gro (7/8 vs 1/7, respectively; P = .01). The data demonstrate that both epinephrine and transoesophageal cardiac pacing are effective within 10 minutes of asphyxia in rats. It is worth noting that transoesophageal cardiac pacing produced a better outcome with respiration and longer survival time compared with epinephrine after restoration of spontaneous circulation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajem.2006.01.024DOI Listing

Publication Analysis

Top Keywords

cardiac pacing
24
transoesophageal cardiac
20
cardiopulmonary resuscitation
12
cardiac
8
benefits cardiopulmonary
8
asphyxial cardiac
8
cardiac arrest
8
treated normal
8
normal saline
8
restoration spontaneous
8

Similar Publications

Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.

View Article and Find Full Text PDF

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Background: Globally, the number of cardiac implantable electronic devices (CIEDs) is increasing. In our study, we aimed to investigate whether CHADS-VASc and RCHADS-VASc scores are predictive of CIED-related complications.

Methods: Our investigation was carried out with a multicenter retrospective design.

View Article and Find Full Text PDF

Objective: To compare the paced QRS duration on different sites in age-, gender-, and indication-matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV-PM).

Method: A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV-PM implantations, respectively. The baseline data of the patients, the pacing site described using three- and nine-partition methods, and the paced QRS duration on 12-lead electrocardiogram were then analyzed.

View Article and Find Full Text PDF

Background: Right ventricular (RV) pacing exacerbates heart failure and increases cardiac mortality in patients with reduced ejection fraction (EF). However, its impact on left ventricular dysfunction in patients with preserved EF remains inconclusive. This study investigates the relationship between RV pacing, global longitudinal strain (GLS), and EF in patients with preserved EF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!