A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Needle insertion into soft tissue: a survey. | LitMetric

Needle insertion into soft tissue: a survey.

Med Eng Phys

Canadian Surgical Technologies & Advanced Robotics (CSTAR), London, Ontario, Canada.

Published: May 2007

Needle insertion in soft tissue has attracted considerable attention in recent years due to its application in minimally invasive percutaneous procedures such as biopsies and brachytherapy. This paper presents a survey of the current state of research on needle insertion in soft tissue. It examines the topic from several aspects, e.g. modeling needle insertion forces, modeling tissue deformation and needle deflection during insertion, robot-assisted needle insertion, and the effect of different trajectories on tissue deformation. All studies show that the axial force of a needle during insertion in soft tissue is the summation of different forces distributed along the needle shaft such as stiffness force, frictional force and cutting force. Some studies have modeled these forces. The force data in some procedures is used for identifying tissue layers as the needle is inserted or for path planning. Needle deflection and tissue deformation are major problems for accurate needle insertion and attempts have been made to model them. Using current models several insertion techniques have been developed which are briefly reviewed in this paper.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2006.07.003DOI Listing

Publication Analysis

Top Keywords

needle insertion
28
insertion soft
16
soft tissue
16
tissue deformation
12
needle
11
tissue
8
insertion
8
needle deflection
8
force
5
soft
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!