Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Bacterial growth is influenced by several different culture conditions. Temperature is one of an essential component which regulates bacterial growth and their morphology. The influence of temperature on the length of bacteria was investigated in broth and on agar in a temperature range from 30.0 degrees C to 47.0 degrees C in 0.5 degrees C steps using a newly developed temperature gradient incubator. The incubator is able to reach a set temperature within 2 h and maintain temperature as accurate as +/-0.1 degrees C of the set temperature. Three Legionella pneumophila serotype 1 strains were incubated for 48 h in BCYE-alpha agar at various temperatures ranging from 30.0 degrees C to 48.0 degrees C and length of bacteria grown at each temperature was microscopically measured. Ability of bacteria to multiply at a given temperature was also determined. L. pneumophila serotype 1 strains ATCC 33152, a clinical isolate Okinawa 02-001 were going to elongate to longer than 100 mum when cultured higher than at 39.5 degrees C and at 41.5 degrees C, respectively. Each strain was unable to multiply when cultured higher than at 44.2 degrees C (ATCC 33152) or at 44.0 degrees C (Okinawa 02-001). Those data would provide insights for establishing regulations in terms of maintaining hot water temperature in a facility where a circulating hot water supply-system is available and contamination with Legionella spp. is likely to happen.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1263/jbb.101.478 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!