A study was undertaken to evaluate exercise performance in 18 dual chamber pacemaker patients believed to be chronotropically incompetent. All patients were paced in a DDD AV synchronous mode at 80 beats per minute (beats/min) as well as an externally triggered, activity responsive VVIR mode. Patients underwent two single blind, randomized symptom-limited treadmill tests (Sheffield protocol). Four of the 18 patients achieved intrinsic rates greater than 100 beats/min and were deleted from the primary study. It was noted that all four of these patients performed best with intrinsic rate response and AV synchrony. Thirteen of the remaining 14 patients demonstrated improved exercise tolerance in the VVIR mode. Average exercise time in the VVIR mode (7:25 +/- 3:12 min) was significantly greater (P less than 0.05) than the DDD mode (6:01 +/- 2:27 min). Work performed was significantly greater (P less than 0.05) in the VVIR mode (4.77 +/- 1.97 METS) than in the DDD mode (3.78 +/- 0.77 METS). Maximum heart rates were 83.86 +/- 5.11 beats/min in DDD mode versus 116.00 +/- 10.56 beats/min in VVIR mode. The results demonstrated that improved exercise tolerance can be achieved with single chamber rate variable pacing compared to DDD pacing in patients with chronotropic incompetence. However, potential symptoms associated with loss of AV synchrony should be ruled out.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1990.tb02082.xDOI Listing

Publication Analysis

Top Keywords

vvir mode
20
ddd mode
12
mode
9
dual chamber
8
activity responsive
8
rate variable
8
demonstrated improved
8
improved exercise
8
exercise tolerance
8
greater 005
8

Similar Publications

Background: Permanent pacemaker implantation has the potential to impact left ventricular (LV) function and hence quality of life (QoL) in the long term.

Aim: To assess the effect of single- and dual-chamber pacing on LV function and QoL.

Methods: This study included 56 patients who underwent permanent pacing: Dual pacing, dual sensing, dual responsive and rate responsive (DDDR) for the initial 3 months and ventricular pacing, ventricular sensing, inhibited response and rate responsive (VVIR) for the next 3 months, and DDDR mode for the last 3 months.

View Article and Find Full Text PDF

Background: Single chamber atrial pacemaker should be sufficient for patients with sinus node dysfunction (SND) with normal atrioventricular (AV) conduction. However, most patients undergo dual chamber pacemaker implantation because of concern of new onset AV block. The annual incidence of new AV block has been reported from 0.

View Article and Find Full Text PDF

Background: The Pacemaker (PM) and Implantable Cardioverter-Defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the voluntary Italian collaborating centers.

Methods: For the year 2022 main data about national PM and ICD implantation activity were obtained on the basis of European Cards and subsequently analyzed to create a standard report.

Results: PM Registry: data about 17 800 PM implantations were collected (14 191 first implants and 3609 replacements).

View Article and Find Full Text PDF

Background: Appropriate programming of cardiovascular implantable electronic devices (CIED) is essential to ensure adequate function and avoid harmful effects. In underdeveloped countries, CIED monitoring and programming are often performed by physicians involved in their implantation. However, many of them often do not have sufficient training in CIED programming.

View Article and Find Full Text PDF

Introduction: The efficacy and safety of leadless cardiac pacemakers (LPMs) as an alternative to conventional transvenous cardiac pacing have been largely reported. The first generation of the Micra transcatheter pacing system (VR; Medtronic) was able to provide single-chamber VVI(R) pacing mode only, with a potential risk of pacemaker syndrome in sinus rhythm patients. A second-generation system (AV) now provides atrioventricular synchrony through atrial mechanical (Am) sensing capability (VDD mode).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!