Background: Vocal cord injuries, postoperative hoarseness, and sore throat are common complications after general anesthesia. One-lung ventilation can be achieved via two techniques: double-lumen endotracheal tube or endobronchial blocker such as the Arndt blocker. The current study was designed to assess the impact of these techniques for one-lung ventilation on the incidence and severity of postoperative hoarseness, vocal cord lesions, and sore throat.

Methods: In this prospective trial, 60 patients were randomly assigned to two groups. One-lung ventilation was achieved with either an endobronchial blocker (blocker group) or a double-lumen-tube (double-lumen group). Postoperative hoarseness and sore throat were assessed at 24, 48, and 72 h after surgery. Bronchial injuries and vocal cord lesions were examined by bronchoscopy immediately after surgery.

Results: In 56 included patients, postoperative hoarseness occurred significantly more frequently in the double-lumen group compared with the blocker group: 44% versus 17%, respectively (P = 0.046). Similar findings were observed for vocal cord lesions: 44% versus 17%, respectively (P = 0.046). The incidence of bronchial injuries was comparable between groups (P = 0.540). Cumulative number of days with hoarseness and sore throat were significantly increased in the double-lumen group compared with the blocker group (P < 0.01). No major complications such as bronchial ruptures were observed.

Conclusions: Clinicians should be aware of an increased incidence of minor airway injuries that may impair patient satisfaction when using a double-lumen tube instead of an endobronchial blocker for one-lung ventilation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000542-200609000-00009DOI Listing

Publication Analysis

Top Keywords

one-lung ventilation
20
endobronchial blocker
16
vocal cord
16
postoperative hoarseness
16
tube endobronchial
12
hoarseness sore
12
sore throat
12
cord lesions
12
blocker group
12
double-lumen group
12

Similar Publications

Introduction: One of the most prevalent healthcare-associated infections in the pediatric intensive care unit is ventilator-associated pneumonia (VAP). VAP not only results in prolonged hospital and intensive care unit (ICU) stays but also imposes higher costs on patients and the healthcare system. Therefore, it is essential to implement preventive measures.

View Article and Find Full Text PDF

One-lung ventilation is commonly used in lateral open chest surgery; however, it can increase pulmonary vascular resistance, which negatively affects Fontan circulation. Nevertheless, one-lung ventilation has a positive indication in post-Fontan patients. It allows surgery with lateral minimally invasive thoracotomy, which does not require a median sternotomy.

View Article and Find Full Text PDF

Clinical Features of COVID-19 Associated Pulmonary Aspergillosis: A Multicenter, Retrospective Study.

Clin Respir J

January 2025

Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.

Objective: This study was conducted to further understand the clinical characteristics of COVID-19 associated pulmonary aspergillosis (CAPA).

Methods: In this study, we conducted a multicenter retrospective survey, which included patients with COVID-19 from five hospitals in Zhejiang, China. A total of 197 patients with COVID-19 were included in the study.

View Article and Find Full Text PDF

Objectives: To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

Materials And Methods: Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy.

View Article and Find Full Text PDF

Introduction/aims: Spirometry is the conventional means to measure lung function in amyotrophic lateral sclerosis (ALS), but is dependent on patient effort and bulbar strength. We aimed to use electric impedance tomography (EIT), an emerging non-invasive imaging modality, to measure dynamic lung volume changes.

Methods: Twenty-one patients with ALS underwent sitting and supine spirometry for forced vital capacity (FVC), and sitting and supine EIT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!