Context: Fusarium keratitis is a serious corneal infection, most commonly associated with corneal injury. Beginning in March 2006, the Centers for Disease Control and Prevention received multiple reports of Fusarium keratitis among contact lens wearers.
Objective: To define the specific activities, contact lens hygiene practices, or products associated with this outbreak.
Design, Setting, And Participants: Epidemiological investigation of Fusarium keratitis occurring in the United States. A confirmed case was defined as keratitis with illness onset after June 1, 2005, with no history of recent ocular trauma and a corneal culture growing Fusarium species. Data were obtained by patient and ophthalmologist interviews for case patients and neighborhood-matched controls by trained personnel. Available Fusarium isolates from patients' clinical and environmental specimens were genotyped by multilocus sequence typing. Environmental sampling for Fusarium was conducted at a contact lens solution manufacturing plant.
Main Outcome Measures: Keratitis infection with Fusarium species.
Results: As of June 30, 2006, we identified 164 confirmed case patients in 33 states and 1 US territory. Median age was 41 years (range, 12-83 years). Corneal transplantation was required or planned in 55 (34%). One hundred fifty-four (94%) of the confirmed case patients wore soft contact lenses. Forty-five case patients and 78 controls were included in the case-control study. Case patients were significantly more likely than controls to report using a specific contact lens solution, ReNu with MoistureLoc (69% vs 15%; odds ratio, 13.3; 95% confidence interval, 3.1-119.5). The prevalence of reported use of ReNu MultiPlus solution was similar between case patients and controls (18% vs 20%; odds ratio, 0.7; 95% confidence interval, 0.2-2.8). Fusarium was not recovered from the factory, warehouse, solution filtrate, or unopened solution bottles; production of implicated lots was not clustered in time. Among 39 isolates tested, at least 10 different Fusarium species were identified, comprising 19 unique multilocus genotypes.
Conclusions: The findings from this investigation indicate that this outbreak of Fusarium keratitis was associated with use of ReNu with MoistureLoc contact lens solution. Contact lens users should not use ReNu with MoistureLoc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1001/jama.296.8.953 | DOI Listing |
Purpose: This study compares and evaluates the parameters of iridotrabecular contact (ITC) in patients with primary angle closure disease (PACD) with natural lenses and pseudophakia based on anterior segment imaging data from swept-source optical coherence tomography (SS-OCT).
Material And Methods: This retrospective study analyzed data from 92 patients aged 32 to 89 years, and included 56 patients with PACD (43 with natural lenses and 13 with pseudophakia) and 36 in the control group (21 with natural lenses and 15 with pseudophakia). All participants underwent SS-OCT (CASIA2; Tomey Corporation, Japan), which included an assessment of the ITC Index and ITC Area.
In this Prentice Medal Award lecture, I shall recount my career in vision science in the context of three types of inspiration-"being inspired," "personal inspiration," and "inspiring others." My research has derived inspiration from a variety of sources, such as contemporary and historical research doyens in the ophthalmic field and beyond, artists, Greek philosophers, and abstract constructs such as principles and adages. A given moment of inspiration can range from being a profound experience to a subtle realization during a quiet moment of reflection.
View Article and Find Full Text PDFIndian J Ophthalmol
December 2024
University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands.
Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).
Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging.
Cureus
November 2024
Ophthalmology, International University of Health and Welfare, Chiba, JPN.
Keratoconus is a condition that causes progressive thinning and anterior protrusion of the cornea. Because of its irregular astigmatism, mild to moderate keratoconus is corrected with hard contact lenses (HCLs), but blepharoptosis due to the long-term wearing of HCLs is often a problem. In this study, we investigated blepharoptosis in HCL wearers with keratoconus.
View Article and Find Full Text PDFCont Lens Anterior Eye
December 2024
Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!