Background: The normal cardiac rhythm originates in the sinoatrial (SA) node that anatomically resides in the right atrium. Malfunction of the SA node leads to various forms of arrhythmias that necessitate the implantation of electronic pacemakers. We hypothesized that overexpression of an engineered HCN construct via somatic gene transfer offers a flexible approach for fine-tuning cardiac pacing in vivo.

Methods And Results: Using various electrophysiological and mapping techniques, we examined the effects of in situ focal expression of HCN1-DeltaDeltaDelta, the S3-S4 linker of which has been shortened to favor channel opening, on impulse generation and conduction. Single left ventricular cardiomyocytes isolated from guinea pig hearts preinjected with the recombinant adenovirus Ad-CMV-GFP-IRES-HCN1-DeltaDeltaDelta in vivo uniquely exhibited automaticity with a normal firing rate (237+/-12 bpm). High-resolution ex vivo optical mapping of Ad-CGI-HCN1-DeltaDeltaDelta-injected Langendorff-perfused hearts revealed the generation of spontaneous action potentials from the transduced region in the left ventricle. To evaluate the efficacy of our approach for reliable atrial pacing, we generated a porcine model of sick-sinus syndrome by guided radiofrequency ablation of the native SA node, followed by implantation of a dual-chamber electronic pacemaker to prevent bradycardia-induced hemodynamic collapse. Interestingly, focal transduction of Ad-CGI-HCN1-DeltaDeltaDelta in the left atrium of animals with sick-sinus syndrome reproducibly induced a stable, catecholamine-responsive in vivo "bioartificial node" that exhibited a physiological heart rate and was capable of reliably pacing the myocardium, substantially reducing electronic pacing.

Conclusions: The results of the present study provide important functional and mechanistic insights into cardiac automaticity and have further refined an HCN gene-based therapy for correcting defects in cardiac impulse generation.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.106.615385DOI Listing

Publication Analysis

Top Keywords

sick-sinus syndrome
12
gene transfer
8
electronic pacemaker
8
impulse generation
8
bioartificial sinus
4
node
4
sinus node
4
node constructed
4
vivo
4
constructed vivo
4

Similar Publications

3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.

Eur Heart J Case Rep

January 2025

AL Qassimi Hospital, Emirates Health Services (EHS), Wasit Street-Al khazamiya, Sharjah 3500, United Arab Emirates.

Background: The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.

Case Summary: A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block.

View Article and Find Full Text PDF

Increasing evidence suggests that Lewy body disease (LBD) is associated with clinically important cardiac complications, including sick sinus syndrome, atrial fibrillation and sudden cardiac death. The high prevalence of sick sinus syndrome and atrial fibrillation in LBD suggests the presence of disease-related atrial conduction disorders. To explore whether LBD is associated with atrial conduction disorders, electrocardiographic (ECG) P wave parameters were analyzed in a cohort of LBD patients (n = 74), using age-matched Alzheimer's disease (AD) patients (n = 25) as controls.

View Article and Find Full Text PDF

Introduction/objective: Atrial fibrillation (AF) could present with slow ventricular-response; bradycardia could facilitate the emergence of AF. The conviction that one "does not succumb" from bradycardia as an escape rhythm will emerge unless one sustains a fatal injury following syncope is in stark difference with ventricular tachyarrhythmia (VA), which may promptly cause cardiac arrest. However, this is not always the case, as a life-threatening situation may emerge during the bradycardic episode, i.

View Article and Find Full Text PDF

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

January 2025

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!