A new technique for the surgical management of unstable thoracolumbar burst fractures: a modification of the anterior approach and an outcome comparison to traditional methods.

Neurosurg Focus

Departments of Neurosurgery and Orthopaedic Surgery, Henry Ford Hospitals, Detroit, Michigan; and Departments of Neurological Surgery, and Orthopaedic Surgery, Division of Spine Surgery, University of Virginia Health Sciences Center, Charlottesville, Virginia.

Published: July 1999

This study was conducted to determine the safety, efficacy, and complication rate associated with the anterior approach in the use of a new titanium mesh interbody fusion cage for the treatment of unstable thoracolumbar burst fractures. The experience with this technique is compared with the senior authors' (C.S., R.W., and M.S.) previously published results in the management of patients with unstable thoracolumbar burst fractures. Between 1996 and 1999, 21 patients with unstable thoracolumbar (T12-L3) burst fractures underwent an anterolateral decompressive procedure in which a titanium cage and Kaneda device were used. Eleven of the 21 patients had sustained a neurological deficit, and all patients improved at least one Frankel grade (average 1.2 grades). There was improvement in outcome in terms of blood loss, correction of kyphosis, and pain, as measured on the Denis Pain and Work Scale, in our current group of patients treated via an anterior approach when compared with the results in those who underwent a posterior approach. In our current study the anterior approach was demonstrated to be a safe and effective technique for the management of unstable thoracolumbar burst fractures. It offers superior results compared with the posterior approach. The addition of the new titanium mesh interbody cage to our previous anterior technique allows the patient's own bone to be harvested from the corpectomy site and used as a substrate for fusion, thereby obviating the need for iliac crest harvest. The use of the cage in association with the Kaneda device allows for improved correction of kyphosis and restoration of normal sagittal alignment in addition to improved functional outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.3171/foc.1999.7.1.5DOI Listing

Publication Analysis

Top Keywords

unstable thoracolumbar
20
burst fractures
20
thoracolumbar burst
16
anterior approach
16
management unstable
8
titanium mesh
8
mesh interbody
8
patients unstable
8
kaneda device
8
correction kyphosis
8

Similar Publications

The Posterior Ligamentous Complex: Anatomic and Biomechanical Considerations in Injury Classification and Management.

J Am Acad Orthop Surg

January 2025

From the Department of Orthopaedics (A. Mo and F. Mo), Medstar Georgetown University Hospital, Washington, DC, and the Department of Orthopaedic Surgery (S. Lockey), University of Virginia, Charlottesville, VA.

The posterior ligamentous complex (PLC) provides critical structural support in the thoracolumbar spine. Its role in resisting progressive flexion is particularly important at the thoracolumbar junction due to the transition from the rigid thoracic spine to the more mobile lumbar region. Each component of the PLC contains anatomic features that contribute to both the structure and function of the PLC as a whole.

View Article and Find Full Text PDF

Introduction Thoracolumbar fractures, particularly burst fractures, represent a significant health concern due to their prevalence and functional impact. This study evaluates the efficacy of short-segment posterior fixation with intermediate screw instrumentation in treating unstable thoracolumbar fractures. Methods A prospective study was conducted from July 2022 to December 2023, including 26 patients with traumatic thoracolumbar fractures.

View Article and Find Full Text PDF

Objective: Spinal vertebral fractures pose a significant healthcare burden due to their frequency and impact on quality of life, resulting in substantial social costs. Minimally invasive surgery (MIS) offers advantages over traditional open surgery (OS), such as reduced tissue damage, less postoperative pain, and shorter hospital stays, although it involves higher implant costs. Research comparing the overall direct costs of these interventions is limited.

View Article and Find Full Text PDF

Study Design: Systematic Literature Review.

Objectives: To address whether TLICS or AOSpine is best used in clinical practice through assessment of interobserver and intraobserver reliability, agreement, and imaging modality performance.

Methods: This systematic literature review was reported in accordance with PRISMA 2020 guidelines.

View Article and Find Full Text PDF

Background: Posterior long-segment instrumentation (PLSI) enables the stable repair of thoracolumbar fractures (TLFx) and is thus widely used. However, patients with highly unstable fractures may experience implant failure and related complications (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!