A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An automated image-processing strategy to analyze dynamic arterial spin labeling perfusion studies. Application to human skeletal muscle under stress. | LitMetric

Arterial spin labeling (ASL) perfusion measurements allow the follow-up of muscle perfusion with high temporal resolution during a stress test. Automated image processing is proposed to estimate perfusion maps from ASL images. It is based on two successive analyses: at first, automated rejection of the image pairs between which a large displacement is detected is performed, followed by factor analysis of the dynamic data and cluster analysis to classify pixels with large signal variation characteristic of vessels. Then, after masking these "vascular" pixels, factor analysis and cluster analysis are further applied to separate the different muscles between low or high perfusion increase, yielding a functional map of the leg. Data from 10 subjects (five normal volunteers and five elite sportsmen) had been analyzed. Resulting time perfusion curves from a region of interest (ROI) in active muscles show a good accordance whether extracted with automated processing or with manual processing. This method of functional segmentation allows automated suppression of vessels and fast visualization of muscles with high, medium or low perfusion, without any a priori knowledge.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2005.09.012DOI Listing

Publication Analysis

Top Keywords

arterial spin
8
spin labeling
8
factor analysis
8
cluster analysis
8
perfusion
7
automated
5
automated image-processing
4
image-processing strategy
4
strategy analyze
4
analyze dynamic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!