The electrophysiology of language comprehension has long been dominated by research on syntactic and semantic integration. However, to understand expressions like "he did it" or "the little girl", combining word meanings in accordance with semantic and syntactic constraints is not enough-readers and listeners also need to work out what or who is being referred to. We review our event-related brain potential research on the processes involved in establishing reference, and present a new experiment in which we examine when and how the implicit causality associated with specific interpersonal verbs affects the interpretation of a referentially ambiguous pronoun. The evidence suggests that upon encountering a singular noun or pronoun, readers and listeners immediately inspect their situation model for a suitable discourse entity, such that they can discriminate between having too many, too few, or exactly the right number of referents within at most half a second. Furthermore, our implicit causality findings indicate that a fragment like "David praised Linda because..." can immediately foreground a particular referent, to the extent that a subsequent "he" is at least initially construed as a syntactic error. In all, our brain potential findings suggest that referential processing is highly incremental, and not necessarily contingent upon the syntax. In addition, they demonstrate that we can use ERPs to relatively selectively keep track of how readers and listeners establish reference.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brainres.2006.06.091DOI Listing

Publication Analysis

Top Keywords

establishing reference
8
language comprehension
8
brain potential
8
implicit causality
8
readers listeners
8
reference language
4
comprehension electrophysiological
4
electrophysiological perspective
4
perspective electrophysiology
4
electrophysiology language
4

Similar Publications

Development of an image quality evaluation system for bedside chest X-ray images using scatter correction processing.

Radiol Phys Technol

January 2025

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.

In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.

View Article and Find Full Text PDF

Detecting Hemorrhagic Myocardial Infarction With 3.0-T CMR: Insights Into Spatial Manifestation, Time-Dependence, and Optimal Acquisitions.

JACC Cardiovasc Imaging

January 2025

Department of Radiology and Imaging Sciences and Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA. Electronic address:

Background: Hemorrhagic myocardial infarction (hMI) can rapidly diminish the benefits of reperfusion therapy and direct the heart toward chronic heart failure. T2∗ cardiac magnetic resonance (CMR) is the reference standard for detecting hMI. However, the lack of clarity around the earliest time point for detection, time-dependent changes in hemorrhage volume, and the optimal methods for detection can limit the development of strategies to manage hMI.

View Article and Find Full Text PDF

Background: Non-small cell lung cancer (NSCLC) is a fatal disease, and radioresistance is an important factor leading to treatment failure and disease progression. The objective of this research was to detect radioresistance-related genes (RRRGs) with prognostic value in NSCLC.

Methods: The weighted gene coexpression network analysis (WGCNA) and differentially expressed genes (DEGs) analysis were performed to identify RRRGs using expression profiles from TCGA and GEO databases.

View Article and Find Full Text PDF

Creutzfeldt-Jakob disease (CJD) is a rare, fatal, and transmissible neurodegenerative disorder caused by prion proteins. Handling specimens from individuals with suspected or confirmed cases presents a safety challenge to hospital workers including clinical laboratory staff. As no national guidelines exist, the clinical pathology laboratory must establish protocols for handling these specimens to ensure sufficient protective measures.

View Article and Find Full Text PDF

: Temporomandibular disorders (TMDs) represent a significant public health issue, among which masticatory muscle pain is the most common. Current publications increasingly indicate surface electromyography (sEMG) as an effective diagnostic tool for muscle dysfunctions that may be employed in TMDs recognition. The objective of this study was to establish reference ranges for TMDs patients with masticatory muscle pain and healthy individuals in the electromyographic Functional Clenching Index (FCI) for the temporalis muscles (TAs) and masseter muscles (MMs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!