Objective: To compare mechanical properties of knotted and crimped nylon loops.

Study Design: In vitro mechanical evaluation.

Sample Population: Loops of 27 kg-test nylon leader. Single strand-clamped square knot compared with 2 crimp systems. Two strand--self-locking knot compared with 2 crimped loops.

Methods: (a) Single pull to failure (n = 10) at 500 mm/min. Initial loop tension (N), peak load (N), peak elongation (mm), stiffness of the linear portion of the curve (N/mm), and failure mode were recorded. (b) Incremental cyclic loading to failure (n = 5)--each loop was cycled 5 times to 100 N at a loading rate of 200 mm/min. Cycling was repeated, with the load increased by 50 N after each set. Elongation (mm), tension remaining (N), and after permanent deformation was present, elongation at 10 N (mm) were measured.

Results: Initial tension and stiffness were greater for crimped loops when compared with knotted loops. There were no differences between crimped loops. The self-locking knot elongated more, and was less stiff, when compared with 2 crimped loops. With incremental loading, knotted loops elongated more than crimped loops. The tension remaining in the loop fell below 10 N more quickly for knotted loops compared with crimped loops.

Conclusion: Crimped loops are stiffer, and resist both static and cyclic load more effectively before becoming permanently elongated, when compared with knotted loops.

Clinical Relevance: Stifle stability will be maintained more effectively by crimped nylon loops when compared with knotted loops.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-950X.2006.00190.xDOI Listing

Publication Analysis

Top Keywords

crimped loops
20
knotted loops
16
compared crimped
12
loops compared
12
compared knotted
12
loops
11
crimped
9
crimp systems
8
crimped nylon
8
knot compared
8

Similar Publications

Aim: To evaluate the three-dimensional position and root resorption of incisors after anterior segment retraction (ASR) using friction versus frictionless mechanics.

Participants And Methods: Thirty female patients (13-18 years) with bimaxillary protrusion were randomly allocated into two groups. In the intervention group, ASR was undertaken using an elastomeric chain rendering 160 g/side extending between mini-screw implant and a hook crimped on 0.

View Article and Find Full Text PDF

The present study has two major purposes: firstly, to investigate whether the analytical model proposed by Jedwab and Clerc for assessing the mechanical behaviour of an open ends metallic braided stent is applicable to the looped ends stent design and secondly, to compare the response of the two stent designs subjected to radial compression. We use finite element analysis to evaluate the performance of the two braided stents emulating well established designs: WALLSTENT and WallFlex. We validate the WALLSTENT model analytically.

View Article and Find Full Text PDF

Objective: To compare in vitro biomechanical properties of the tube knot (TB) to a crimp clamp (CC) system, and square knot (SQ) using 3 monofilament materials.

Study Design: In vitro biomechanical study.

Sample Population: Suture loops (n=20 per material/knot construct).

View Article and Find Full Text PDF

Objective: To biomechanically compare different loop and crimp configurations used for extracapsular suture stabilization of the CCL-deficient stifle.

Study Design: In vitro study.

Sample Population: Crimped loop constructs of 100 lb Ande type nylon leader line in 7 different configurations comprising single and double loops, single and double crimps, and the interlocking loop configuration.

View Article and Find Full Text PDF

Safe extraction of Riata looped extruding filler cables.

J Cardiovasc Electrophysiol

August 2013

Greenville Health System, University Medical Group, Greenville, South Carolina, USA.

The Riata 1590 lead model contains both electrically active cables (AC) and filler cables (FC) that run in pairs within lumens along the lead body. FC are yet to be described as lead components that may be externalized from either external abrasion or inside-out abrasion seen in the recalled St. Jude leads.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!