This paper discusses the effects of measurement uncertainties when calculating elastic moduli of laryngeal tissue. Small dimensions coupled with highly nonlinear elastic properties exacerbate the uncertainties. The sensitivity of both tangent and secant Young's Modulus was quantified in terms of the coefficient of variation, which depended on measurement of reference length and cross-sectional area. Uncertainties in the measurement of mass, used to calculate cross-sectional area of a small tissue sample, affected Young's Modulus calculations when tissue absorption of the hydrating solution was not accounted for. Uncertainty in reference length had twice the effect on elasticity than other measures. The implication of these measurement errors on predicted fundamental frequency of vocalization is discussed. Refinements on isolated muscle experimental protocols are proposed that pay greatest attention to measures of highest sensitivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4778974PMC
http://dx.doi.org/10.1016/j.jvoice.2006.06.004DOI Listing

Publication Analysis

Top Keywords

elastic properties
8
measurement uncertainties
8
fundamental frequency
8
young's modulus
8
reference length
8
cross-sectional area
8
measurement
5
sensitivity elastic
4
properties measurement
4
uncertainties
4

Similar Publications

Protein-based biomaterials are in high demand due to their high biocompatibility, non-toxicity, and biodegradability. In this study, we explore the bacterial secreted protein A (EspA), which self-assembles into long extracellular filaments, as a potential building block for new protein-based biomaterials. We investigated the morphological and mechanical properties of EspA filaments and how protein engineering can modify them.

View Article and Find Full Text PDF

The objectives of this case series study were to test whether an elastic back exosuit could increase a wearer's endurance when lifting heavy objects and to assess whether lifting more cancels out the exosuit's risk reduction benefits. We found that 88% of participants increased their lifting repetitions while wearing an exosuit, with endurance increases ranging from 28 to 75%. We then used these empirical data with an ergonomic assessment model based on fatigue failure principles to estimate the effects on cumulative back damage (an indicator of low back disorder risk) when an exosuit is worn and more lifts are performed.

View Article and Find Full Text PDF

Cryogenic, but not hypothermic, preservation disrupts the extracellular matrix of cell sheets.

Bioact Mater

April 2025

3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Rua Ave 1, Edifício 1 (Sede), 4805-694 Barco, Guimarães, Portugal.

Cell sheet (CS)-based approaches hold significant potential for tissue regeneration, relying on the extracellular matrix (ECM) for success. Like in native tissues, the ECM provides structural and biochemical support for cellular homeostasis and function. Effective preservation strategies that maintain ECM integrity are critical to enhance the therapeutic potential of CS-based approaches.

View Article and Find Full Text PDF

The present study focuses on the ground state mechanical, acoustic, thermodynamic and electronic transport properties of NaSbS polymorphs using the density functional theory (DFT) and semi-classical Boltzmann transport theory. The mechanical stability of the polymorphs is affirmed by the calculated elastic tensor. The calculated elastic properties asserted that all the polymorphs exhibit soft, brittle, anisotropic nature containing dominant covalent bonding.

View Article and Find Full Text PDF

Glycosylation can be used to improve the emulsifying properties of protein by covalently binding with sugar. In this study, we prepared coconut protein (CP) -polygalacturonic acid (PA) conjugates by dry-heat method, studied the effect of PA with different molecular weight on the structure and functionality of CP, and characterized the interfacical behavior of CP at the oil-water interface to establish the relationship between interfacial behavior and emulsion stability. The results showed that different molecular weights of PA (28.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!