Background And Purpose: Many technologies have been mooted as equal to transurethral resection of the prostate (TURP) without gaining widespread acceptance because of the lack of randomized trials. The Greenlight laser system (Laserscope, San Jose, Ca.), an 80 W system for photovaporization of the prostate (PVP), was compared with TURP in such a trial.
Patients And Methods: A series of 120 patients was randomized to undergo TURP or PVP after evaluation, which was repeated at 1, 3, 6, and 12 months after treatment. Irrigation use, length of catherization (LOC), length of hospital stay (LOS), postvoiding residual volume, sexual function, blood loss, cost, and operative time also were assessed.
Results: To date, 76 patients are evaluable. Both groups showed a significant (P < 0.5) increase in maximum flow rate from baseline. In the TURP group, flow increased from 8.7 to 17.9 mL/sec (149%) and in the PVP group from 8.5 to 20.6 mL/sec (167%). The International Prostate Symptom Score decreased from 25.4 to 12.4(50.23%) in the TURP group and from 25.7 to 12.0 (49.83%) in the PVP group. Postvoiding residual volumes also showed significant decreases. Similar trends were seen in relation to bother and quality of life scores. There was no difference in sexual function as measured by a questionnaire. The LOC was significantly less in the PVP group (P < 0.001), the mean being 12.2 hours (range 0-24 hours) versus 44.5 hours for TURP (range 6-192 hours). A similar situation was seen in relation to LOS (P < 0.0001), with the mean of the PVP group being 1.08 days (range 1-2 days) and the mean for the TURP group being 3.4 days (range 3-9 days). Adverse events were less frequent in the PVP group, and the costs were 22% less.
Conclusions: This trial demonstrates that PVP is effective compared with TURP, producing equivalent improvements in flow rates and IPSS with markedly reduced LOS, LOC, and adverse events. Long-term follow- up is being undertaken to assess the durability of these results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/end.2006.20.580 | DOI Listing |
J Hepatocell Carcinoma
January 2025
School of Medicine, University of Electronic Science and Technology, Sichuan, China.
Objective: This study aimed to investigate how dynamic contrast-enhanced CT imaging signs correlate with the differentiation grade and microvascular invasion (MVI) of hepatocellular carcinoma (HCC), and to assess their predictive value for MVI when combined with clinical characteristics.
Methods: We conducted a retrospective analysis of clinical data from 232 patients diagnosed with HCC at our hospital between 2021 and 2022. All patients underwent preoperative enhanced CT scans, laboratory tests, and postoperative pathological examinations.
Evid Based Dent
January 2025
Doctoral Research Fellow and Specialty Trainee (Endodontics), School of Dental Sciences, Faculty of Medical Sciences, Newcastle University, Newcastle Upon Tyne, UK.
Aims: This study aimed to assess the effectiveness of a novel antimicrobial gel, containing copper and silver nanoparticles, for use in root canal disinfection.
Methods: Copper and silver-based gels were created in-house, using a support network of biocompatible polymers, including polyvinyl alcohol (PVA), polyvinyl pyrrolidone (PVP), and polyethylene glycol (PEG). Six experimental groups were created, three containing silver ions and three copper ions, where the PVA, PVP and PEG ratios were also adjusted in each group to test the gel's physical state.
Pharmaceutics
December 2024
AbbVie Deutschland GmbH & Co. KG, Knollstraße, 67061 Ludwigshafen am Rhein, Germany.
Atomization plays a key role in spray drying, a process widely used in the pharmaceutical, chemical, biological, and food and beverage industries. In the pharmaceutical industry, spray drying is particularly important in the preparation of amorphous solid dispersions, which enhance the bioavailability of active pharmaceutical ingredients when mixed with a polymer. In this study, a 3D-printed adaptation of a commercial spray dryer nozzle (PHARMA-SD PSD-1, GEA Group AG) was used to investigate the atomization of PVP-VA 64 polymer solutions under varying flow conditions using high-speed diffuse back-illumination.
View Article and Find Full Text PDFJ Robot Surg
January 2025
Department of Orthopaedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu, China.
The rising incidence of osteoporotic vertebral compression fractures (OVCF) has increased the demand for precise treatments like robot-assisted percutaneous vertebroplasty (PVP), especially for conditions like Kümmell's disease that require high surgical accuracy. However, the traditional tracer fixation method has certain limitations. This study aimed to compare the safety and clinical efficacy of a modified tracer fixation technique with the traditional fixation method in robot-assisted percutaneous vertebroplasty (PVP) for Kümmell's disease.
View Article and Find Full Text PDFWorld Neurosurg
December 2024
Department of Orthopaedics, PLA Rocket Force Medical Center, Beijing, 100088, China. Electronic address:
Background: Percutaneous vertebroplasty (PVP) is a common surgical method for osteoporotic vertebral compression fracture (OVCFs). The puncture method and location of the puncture needle can directly affect bone cement distribution in the vertebra. This retrospective study aimed to compare the clinical efficacy and safety of PVP using the cross-puncture and bilateral conventional puncture for the treatment of Genant grade 0-1 OVCFs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!