It is well known that the hematocrit in microvessels with diameters smaller than 1000 microm is lower than either venous or arterial hematocrit, thereby resulting in significantly lower mean hematocrit values for vessels perfusing a given tissue (i.e., lower tissue hematocrit). The mechanisms that underlie this reduction of microvascular hematocrit include axial migration, plasma skimming and the Fahraeus Effect. It has been previously demonstrated in rats that a linear hematocrit gradient normally exists through the thickness of the left ventricular myocardium, and that this gradient is sensitive to alterations of the rheological properties of the circulating blood. The gradient is abolished if the RBC in the perfusate are rigid; fibrinogen infusions, and thus increases of both plasma viscosity and RBC aggregation, also affect this gradient. In a new series of studies, it has been observed that enhanced RBC aggregation affects the myocardial hematocrit gradient regardless of alterations of plasma viscosity. Although the exact mechanisms responsible for the myocardial hematocrit gradient, as well as its physiological significance, are not yet clearly known, it is possible to speculate that alterations in local hematocrit could adversely affect myocardial perfusion and function.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hematocrit gradient
12
hematocrit
10
tissue hematocrit
8
hematocrit values
8
plasma viscosity
8
rbc aggregation
8
myocardial hematocrit
8
gradient
6
hemorheological parameters
4
parameters determinants
4

Similar Publications

Development and validation of a quantification method for direct oral anticoagulants from capillary blood using volumetric absorptive microsampling and online SPE-LC-MS.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, University of Muenster, Muenster, Germany. Electronic address:

The number of prescriptions for new direct oral anticoagulants (DOACs) apixaban, edoxaban, rivaroxaban and dabigatran has increased exponentially in recent years, increasingly replacing the old gold standard, vitamin-K-antagonists. Due to their wide therapeutic range, therapeutic drug monitoring (TDM) is not required, although it has been proven that this could significantly reduce side effects. In order to develop a cost-efficient and simple method for the simultaneous detection of the DOACs and phenprocoumon, a new technology for sample preparation from capillary blood in the ambulant sector named VAMS® was integrated and an LC-MS detector with on-line solid phase extraction (SPE) applying a Turboflow HTLC Cyclone 1.

View Article and Find Full Text PDF

Background: Patients with severe dengue who develop severe respiratory failure requiring mechanical ventilation (MV) support have significantly increased mortality rates. This study aimed to develop a robust machine learning-based risk score to predict the need for MV in children with dengue shock syndrome (DSS) who developed acute respiratory failure.

Methods: This single-institution retrospective study was conducted at a tertiary pediatric hospital in Vietnam between 2013 and 2022.

View Article and Find Full Text PDF

GPVI-mediated thrombus stabilization of shear-induced platelet aggregates in a microfluidic stenosis.

Biophys J

January 2025

Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania; Department of Surgery, Penn State College of Medicine, Hershey, Pennsylvania. Electronic address:

Supraphysiological shear rates (>2000 s) amplify von Willebrand factor unfurling and increase platelet activation and adhesion. These elevated shear rates and shear rate gradients also play a role in shear-induced platelet aggregation (SIPA). The primary objective of this study is to investigate the contributions of major binding receptors to platelet deposition and SIPA in a stenotic model.

View Article and Find Full Text PDF

Purpose: To present a first principle-based, high-fidelity computational model for predicting full three-dimensional (3D) and time-resolved retinal microvascular hemodynamics taking into consideration the flow and deformation of individual blood cells.

Methods: The computational model is a 3D fluid-structure interaction model based on combined finite volume/finite element/immersed-boundary methods. Three in silico microvascular networks are built from high-resolution in vivo motion contrast images of the superficial capillary plexus in the parafoveal region of the human retina.

View Article and Find Full Text PDF

Characterization of the phagocytic ability of white blood cells separated using a single curvature spiral microfluidic device.

Biomed Eng Lett

November 2024

Department of Mechanical Engineering, BITS-Pilani, K K Birla Goa Campus, Goa, 403726 India.

Article Synopsis
  • This study introduces a microfluidic device designed to efficiently separate white blood cells (WBCs) from red blood cells (RBCs) for the Nitroblue Tetrazolium (NBT) bioassay, which measures phagocytic activity in cells.
  • The device successfully removes 99.99% of RBCs from WBC samples, improving the RBC to WBC ratio from 848:1 to 2:3, and is effective even at a hematocrit concentration of 1% blood.
  • The microfluidic device is easy to fabricate, cost-effective, and can process a single drop of blood in under 10 minutes, without the need for complex methods like RBC lysis or expensive
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!