The delivery accuracy of radiation therapy for pulmonary and abdominal tumors suffers from tumor motion due to respiration. Respiratory gating should be applied to avoid the use of a large target volume margin that results in a substantial dose to the surrounding normal tissue. Precise respiratory gating requires the exact spatial position of the tumor to be determined in real time during treatment. Usually, fiducial markers are implanted inside or next to the tumor to provide both accurate patient setup and real-time tumor tracking. However, current tumor tracking systems require either substantial x-ray exposure to the patient or large fiducial markers that limit the value of their application for pulmonary tumors. We propose a real-time tumor tracking system using implanted positron emission markers (PeTrack). Each marker will be labeled with low activity positron emitting isotopes, such as 124I, 74As, or 84Rb. These isotopes have half-lives comparable to the duration of radiation therapy (from a few days to a few weeks). The size of the proposed PeTrack marker will be 0.5-0.8 mm, which is approximately one-half the size of markers currently employed in other techniques. By detecting annihilation gammas using position-sensitive detectors, multiple positron emission markers can be tracked in real time. A multimarker localization algorithm was developed using an Expectation-Maximization clustering technique. A Monte Carlo simulation model was developed for the PeTrack system. Patient dose, detector sensitivity, and scatter fraction were evaluated. Depending on the isotope, the lifetime dose from a 3.7 MBq PeTrack marker was determined to be 0.7-5.0 Gy at 10 mm from the marker. At the center of the field of view (FOV), the sensitivity of the PeTrack system was 240-320 counts/s per 1 MBq marker activity within a 30 cm thick patient. The sensitivity was reduced by 45% when the marker was near the edge of the FOV. The scatter fraction ranged from 12% (124I, 74As) to 16% (84Rb). In addition, four markers (labeled with 124I) inside a 30 cm diameter water phantom were simulated to evaluate the feasibility of the multimarker localization algorithm. Localization was considered successful if a marker was localized to within 2 mm from its true location. The success rate of marker localization was found to depend on the number of annihilation events used and the error in the initial estimate of the marker position. By detecting 250 positron annihilation events from 4 markers (average of 62 events per marker), the marker success rates for initial errors of +/-5, +/-10, and +/-15 mm were 99.9%, 99.6%, and 92.4%, respectively. Moreover, the average localization error was 0.55 (+/-0.27) mm, which was independent of initial error. The computing time for localizing four markers was less than 20 ms (Pentium 4, 2.8 GHz processor, 512 MB memory). In conclusion, preliminary results demonstrate that the PeTrack technique can potentially provide real-time tumor tracking with low doses associated with the marker's activity. Furthermore, the small size of PeTrack markers is expected to facilitate implantation and reduce patient risk.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2207213DOI Listing

Publication Analysis

Top Keywords

tumor tracking
20
real-time tumor
16
positron emission
12
emission markers
12
petrack marker
12
marker
11
markers
10
implanted positron
8
radiation therapy
8
respiratory gating
8

Similar Publications

Background: The results of many large randomized clinical trials (RCTs) have transformed clinical practice in gastroesophageal reflux disease (GERD) and esophageal hiatal hernia (HH). However, research waste (i.e.

View Article and Find Full Text PDF

Background: Rates of venous thromboembolism (VTE) recurrence and bleeding remain high in patients with cancer who are prescribed anticoagulants (ACs) such as low-molecular-weight heparin (LMWH) after an initial VTE event.

Objectives: To identify patient characteristics associated with VTE recurrence and bleeding in patients receiving LMWH for cancer-associated VTE and to explore secondary AC management and clinical outcomes in these patients.

Methods: An observational study was conducted using nationwide French data for adults with active cancer who were hospitalized with VTE in 2013-2018 and were reimbursed for LMWH ≤ 30 days after hospital discharge.

View Article and Find Full Text PDF

Noninvasive in vivo imaging of macrophages: understanding tumor microenvironments and delivery of therapeutics.

Biomark Res

January 2025

BK21 FOUR KNU Convergence Educational Program of Biomedical Sciences for Creative Future Talents, Department of Biomedical Sciences, School of Medicine, Kyungpook National University, Daegu, 41944, Korea.

Macrophages are pivotal in the body's defense and response to inflammation. They are present in significant numbers and are widely implicated in various diseases, including cancer. While molecular and histological techniques have advanced our understanding of macrophage biology, their precise function within the cancerous microenvironments remains underexplored.

View Article and Find Full Text PDF

: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.

View Article and Find Full Text PDF

: Inadequate dosing and respiratory motion contribute to local recurrence for oligometastatic disease (OMD). While short-term LC rates are well-documented, data on long-term LC remain limited. This study investigated long-term LC after stereotactic body radiotherapy (SBRT), using respiratory motion management techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!