Objectives: We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation.

Materials And Methods: A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis.

Results: The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications.

Conclusions: The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.rli.0000233326.94998.b0DOI Listing

Publication Analysis

Top Keywords

distal radius
24
radius fractures
24
diagnostic performance
16
forearm fractures
12
fractures
10
müller-ao frykman
8
screen-film radiography
8
storage-phosphor radiography
8
flat-panel detector
8
detector system
8

Similar Publications

Background: Distal biceps tendon rupture is an injury that causes a significant reduction in strength and endurance. Combined cortical button and interference screw fixation has been utilized via single-incision technique. There are limited data describing this technique utilizing a double-incision approach.

View Article and Find Full Text PDF

High resolution peripheral quantitative computed tomography (HRpQCT) offers detailed bone geometry and microarchitecture assessment, including cortical porosity, but assessing chronic kidney disease (CKD) bone images remains challenging. This proof-of-concept study merges deep learning and machine learning to 1) improve automatic segmentation, particularly in cases with severe cortical porosity and trabeculated endosteal surfaces, and 2) maximize image information using machine learning feature extraction to classify CKD-related skeletal abnormalities, surpassing conventional DXA and CT measures. We included 30 individuals (20 non-CKD, 10 stage 3 to 5D CKD) who underwent HRpQCT of the distal and diaphyseal radius and tibia and contributed data to develop and validate four different AI models for each anatomical site.

View Article and Find Full Text PDF

BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.

View Article and Find Full Text PDF

HIV-related mortality has fallen due to scale-up of antiretroviral therapy (ART), so more women living with HIV (WLH) now live to reach menopause. Menopausal estrogen loss causes bone loss, as do HIV and certain ART regimens. However, quantitative bone data from WLH are few in Africa.

View Article and Find Full Text PDF

Background: Radial bowing is necessary for forearm rotation. Fractures or deformities of the forearm that affect the radial bow may disrupt normal forearm rotation.

Objective: The purpose of this study was to evaluate the development and establish normative values for the pediatric and adolescent radial bow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!