A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of the thermal conductivity of individual carbon nanotubes by the four-point three-omega method. | LitMetric

Measurement of the thermal conductivity of individual carbon nanotubes by the four-point three-omega method.

Nano Lett

Laboratory of Thermodynamics in Emerging Technologies, ETH, Zurich, Switzerland.

Published: August 2006

The thermal conductivity of individual multiwalled carbon nanotubes was measured by utilizing the four-point-probe third-harmonic method, based on the fact that the third harmonic amplitude and phase as a response to applied alternate current at fundamental frequency, omega, can be expressed in terms of thermal conductivity and diffusivity. To this end, a microfabricated device composed of four metal electrodes was modified to manufacture nanometer-sized wires by using a focused ion beam source. A carbon nanotube could then be suspended over a deep trench milled by the focused ion beam, preventing heat loss to the substrate. Compared with the two-point-probe technique, a significant improvement in accuracy is assured by using four probes, because the contact contribution to the determination of the thermal conductivity is eliminated, making it possible to measure the correct signals of first and third harmonics. The multiwalled carbon nanotube was modeled as a one-dimensional diffusive energy transporter and its thermal conductivity was measured at room temperature under vacuum to be 300 +/- 20 W/mK.

Download full-text PDF

Source
http://dx.doi.org/10.1021/nl060331vDOI Listing

Publication Analysis

Top Keywords

thermal conductivity
20
conductivity individual
8
carbon nanotubes
8
multiwalled carbon
8
focused ion
8
ion beam
8
carbon nanotube
8
conductivity
5
measurement thermal
4
carbon
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!