Objective: We examined the efficacy of drug-eluting stent (DES) implantation (Sirolimus or Paclitaxel) in patients with ischemic cardiomyopathy and severe left ventricular (LV) dysfunction and compared the outcome with a similar group of patients undergoing bare metal stent (BMS) implantation.
Background: Patients with severe LV dysfunction are a high risk group. DES may improve the long term outcomes compared with BMS.
Methods: One hundred and ninety one patients (23% women) with severe LV dysfunction (LV ejection fraction < or =35%) underwent coronary stent implantation between May 2002 and May 2005 and were available for follow-up. One hundred and twenty eight patients received DES (Sirolimus in 72 and Paclitaxel in 54) and 63 patients had BMS. Patients with acute S-T elevation myocardial infarction (STEMI) were excluded. The primary endpoint was cardiovascular mortality. A composite endpoint of major adverse cardiac events (MACE) including cardiovascular mortality, myocardial infarction (MI), and target vessel revascularization (TVR) was the secondary endpoint.
Results: Mean follow-up was 420 +/- 271 days. No differences were noted in age (69 +/- 10 years vs. 70 +/- 10 years, P = NS), number of vessel disease (2.3 +/- 0.7 vs. 2.2 +/- 0.8, P = NS), history of congestive heart failure (47% vs. 46%, P = NS), MI (60% vs. 61%, P = NS), or number of treated vessels (1.3 +/- 0.5 vs. 1.3 +/- 0.6, P = NS) for the DES and BMS group, respectively. Diabetes was more common among DES patients (45% vs. 25%, P = 0.01). The left ventricular ejection fraction (LVEF) was similar between the two groups (28% +/- 6% vs. 26% +/- 8%, P = NS for the DES and BMS, respectively). During the follow-up, there were a total of 25 deaths of which two were cancer related (2 in DES group). There were 23 cardiac deaths, 8/126 (6%) which occurred in the DES group and 15/63 (24%) in the BMS group (P = 0.05 by log-rank test). MACE rate was 10% for the DES group and 41% for the BMS group (P = 0.003). NYHA class improved in both groups (from 2.5 +/- 0.8 to 1.7 +/- 0.8 in DES and from 2 +/- 0.8 to 1.4 +/- 0.7 in the BMS, P = NS).
Conclusion: Compared with bare-metal stents, DES implantation reduces mortality and MACE in high risk patients with severe left ventricular dysfunction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.20833 | DOI Listing |
Ultrasound J
January 2025
Pediatric Emergency Medicine, Yale University School of Medicine, 100 York Street, Suite 1F, New Haven, CT, 06511, USA.
E-point septal separation (EPSS) and tricuspid annular plane systolic excursion (TAPSE) are M-mode measures of left and right ventricular systolic function, with limited pediatric point-of-care ultrasound (POCUS) research. We conducted a cross-sectional study in a pediatric emergency department, enrolling 12-17-year-olds without cardiopulmonary complaints. Exclusion criteria included abnormal vital signs, fever, altered mental status, or psychiatric illness.
View Article and Find Full Text PDFPediatr Cardiol
January 2025
Echocardiography Laboratory, Instituto Dante Pazzanese de Cardiologia, São Paulo, Brazil.
This study aimed to evaluate the hemodynamic and ventricular performance of neonates with hypoxic-ischemic encephalopathy (HIE) undergoing therapeutic hypothermia using conventional and advanced echocardiographic techniques. This observational, prospective study included 22 neonates with HIE matched with 22 healthy neonates. Echocardiographic studies were performed 24 h after achieving target temperature during hypothermia and 24 h after rewarming.
View Article and Find Full Text PDFMinerva Cardiol Angiol
January 2025
Department of Anatomy and Embryology, Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands.
The assessment of myocardial function and its coupling with the arterial system, called ventricular-arterial coupling (VAC), is of paramount importance in many clinical fields, from arterial hypertension, which is the main cause of cardiovascular diseases and death, to heart failure. VAC has been the subject of studies for several decades both from an energetic cost and the impact it can exert on cardiovascular performance. Although more attention has been paid to the relationship between the left ventricle and the left arterial circuit in compromised hemodynamic stages, VAC has aroused interest in many other aspects of study, from its application in pathologies of the right sections of the heart to its clinical impact in prevention and cardiovascular risk factors.
View Article and Find Full Text PDFJACC Cardiovasc Interv
December 2024
William Beaumont University Hospital, Corewell Health East, Royal Oak, Michigan, USA. Electronic address:
Minerva Anestesiol
January 2025
Transplant Anesthesia and Critical Care, Pisa NHS and University Hospitals, Pisa, Italy -
Intraoperative hemodynamic monitoring is crucial for managing patients with end-stage liver disease (ESLD) undergoing orthotopic liver transplantation (OLT) due to their complex cardiovascular and pulmonary abnormalities. Traditionally, pulmonary artery catheterization (PAC) has been the standard for hemodynamic monitoring during OLT. However, the use of transesophageal echocardiography (TEE) has increased due to its real-time visualization of cardiac and vascular structures, which aids in managing hemodynamic instability during the three surgical phases of OLT: pre-anhepatic, anhepatic, and neo-hepatic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!