A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectral response variation of a negative-electron-affinity photocathode in the preparation process. | LitMetric

Spectral response variation of a negative-electron-affinity photocathode in the preparation process.

Appl Opt

School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China.

Published: August 2006

AI Article Synopsis

  • The study investigates how the spectral response of a negative electron affinity (NEA) photocathode, specifically a GaAs photocathode, changes during its preparation through two main experiments.
  • An automatic spectral response recording system measures the photocathode's performance in situ, revealing significant changes during the activation and sealing processes.
  • Results indicate that the spectral response degrades, particularly at longer wavelengths during sealing, impacting the overall effectiveness of devices like night-vision goggles.

Article Abstract

In order to research the spectral response variation of a negative electron affinity (NEA) photocathode in the preparation process, we have done two experiments on a transmission-type GaAs photocathode. First, an automatic spectral response recording system is described, which is used to take spectral response curves during the activation procedure of the photocathode. By this system, the spectral response curves of a GaAs:Cs-O photocathode measured in situ are presented. Then, after the cathode is sealed with a microchannel plate and a fluorescence screen into the image tube, we measure the spectral response of the tube by another measurement instrument. By way of comparing and analyzing these curves, we can find the typical variation in spectral-responses. The reasons for the variation are discussed. Based on these curves, spectral matching factors of a GaAs cathode for green vegetation and rough concrete are calculated. The visual ranges of night-vision goggles under specific circumstances are estimated. The results show that the spectral response of the NEA photocathode degraded in the sealing process, especially at long wavelengths. The variation has also influenced the whole performance of the intensifier tube.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.45.006094DOI Listing

Publication Analysis

Top Keywords

spectral response
28
spectral
8
response variation
8
photocathode preparation
8
preparation process
8
nea photocathode
8
response curves
8
photocathode
6
response
6
variation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!