Objective: To examine the diagnostic accuracy of clinical examination to determine fetal presentation in late pregnancy.

Design: Cross sectional analytic study with index test of clinical examination and reference standard of ultrasonography.

Setting: Antenatal clinic in tertiary obstetric hospital in Sydney, Australia.

Participants: 1633 women with a singleton pregnancy between 35 and 37 weeks' gestation attending antenatal clinics.

Intervention: Fetal presentation assessed by clinical examination during routine antenatal care, followed by ultrasonography to confirm the diagnosis.

Main Outcome Measures: Sensitivity, specificity, and positive and negative predictive values of clinical examination compared with ultrasonography. Diagnostic rates by maternal characteristics.

Results: Ultrasonography identified non-cephalic presentation in 130 (8%) women, comprising 103 (6.3%) with breech and 27 (1.7%) with transverse or oblique lie. Sensitivity of clinical examination for detecting non-cephalic presentation was 70% (95% confidence interval 62% to 78%) and specificity was 95% (94% to 96%). The positive predictive value and negative predictive value were 55% and 97%, respectively.

Conclusions: Clinical examination is not sensitive enough for detection and timely management of non-cephalic presentation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1570002PMC
http://dx.doi.org/10.1136/bmj.38919.681563.4FDOI Listing

Publication Analysis

Top Keywords

clinical examination
28
non-cephalic presentation
16
diagnostic accuracy
8
accuracy clinical
8
presentation late
8
cross sectional
8
sectional analytic
8
analytic study
8
fetal presentation
8
negative predictive
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!