Immunoassays are used worldwide for the rapid screening of drugs. Despite the fact that they are highly valuable tools for the testing of legal and illicit drugs, there is a non-negligable risk of false-positive and false-negative findings and many pitfalls must be taken into account when using these tests in an uncritical manner and without valid confirmation procedures. In order to check the correlation between cloned-enzyme donor immunoassay (CEDIA) readings and exact determined gas chromatography/mass spectrometry (GC/MS) values for benzoylecgonine, a total of 472 serum samples was measured with an immunoassay (CEDIA) as well as GC/MS. As a result, it was shown that in the lower area of concentration, up to approx. 300 ng equ. benzoylecgonine/ml, there is a semiquantitative useful correlation. With higher concentrations, the values shift more and more apart and many runaways are visible. Generally the use of tests for materials other than those declared is excluded from the manufacturer's warranty and is at the user's own risk, but the authors found that many immunochemical tests with a certification only for the use in urine are well suited to the screening of serum samples, and even low readings could be confirmed by GC/MS. With blood or serum as sample, it could be regularly observed that generally very small readings could not only be confirmed with mass spectrometry but could in most cases also be quantified. This was the key factor in determining the rate of confirmation in 495 cases. In total, an incredibly high reliability for the CEDIA cocaine test (via benzoylecgonine) was shown up to the area of detection (detection limit), far below the cut-off. These results confirm the extraordinary sensitivity and specificity of this test also for blood or serum as sample material to be tested.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0031-1296743 | DOI Listing |
Scand J Clin Lab Invest
April 2024
Department of Laboratory Medicine, Clinical Chemistry, Örebro University Hospital, Örebro, Sweden.
Natural and semi-synthetic cannabinoid analogs are getting increasing media attention for their recreative use as an alternative to traditional cannabis, in Sweden as well as internationally. To investigate an increasing number of urine samples incoming to our clinical laboratory that were screening positive, using a CEDIA THC-COOH immunoassay from ThermoFisher Scientific, but then testing negative using GC-MS based verification analysis, we developed an LC-MS/MS-method for verification of hexahydrocannabinol (HHC) and Δ8-tetrahydrocannabinol. Assessment of HHC intake was based on identification of the following four metabolites: 11-nor-9(R)-carboxy-hexahydrocannabinol (R-HHC-COOH), 11-nor-9(S)-carboxy-hexahydrocannabinol (S-HHC-COOH), 11-hydroxy-9(R)-hexahydrocannabinol (R-HHC-OH) and 11-hydroxy-9(S)-hexahydrocannabinol (S-HHC-OH).
View Article and Find Full Text PDFJ Anal Toxicol
November 2023
Department of Pathology, Virginia Commonwealth University, Box 980165, Richmond, VA 23298-0165, USA.
There has been an exponential surge in the presence and use of cannabinoids since the federal legalization of hemp (Agricultural Improvement Act of 2018). This growth is attributed to delta-9-tetrahydrocannabinol (delta-9-THC) and cannabidiol (CBD), the most abundant phytocannabinoid components of cannabis and hemp, respectively, but with many other emerging THC analogs. Structurally, these analogs are similar to delta-9-THC, yet very little information is available about their potency and even less information is available regarding their detectability using commercially available cannabinoid screening kits.
View Article and Find Full Text PDFJ Anal Toxicol
May 2023
Forensic Toxicology Laboratory, Department of Pathology, Immunology and Laboratory Medicine, University of Florida College of Medicine, 4800 SW 35th Drive, Gainesville, FL 32608, USA.
Laws concerning the growing, selling and consuming of cannabis and its related products have been changing considerably over the last few years. The legalization of hemp in 2018 sparked an interest in ∆9-tetrahydrocannabinol (∆9-THC) isomers and analogs that are derived from hemp and sold with minimal oversight. One example is ∆8-tetrahydrocannabinol (∆8-THC).
View Article and Find Full Text PDFJ Anal Toxicol
March 2023
Clinical Biochemistry Unit, Alfred Health, 55 Commercial Rd, Melbourne, VIC 3004, Australia.
Immunoassays are routinely used to provide rapid urine drug screening results in the clinical setting. These screening tests are prone to false-positive results and ideally require confirmation by mass spectrometry. In this study, we have examined a large number of urine specimens where drugs other than amphetamines may have caused a false-positive amphetamine immunoassay screening result.
View Article and Find Full Text PDFJ Appl Lab Med
October 2022
Department of Pathology and Laboratory Medicine, Dartmouth-Hitchcock Health System, Lebanon, NH, USA.
Background: Loperamide (Imodium®), a commonly used anti-diarrheal, is a mu opioid receptor agonist that, like all opioids, reduces gastrointestinal tract peristalsis. Loperamide is considered to have low abuse potential as it does not produce an analgesic or euphoric effect due to low bioavailability and first-pass metabolism. However, reports of individuals misusing loperamide through the use of super-therapeutic doses, alone or in combination with P-glycoprotein and/or CYP450 enzyme inhibitors, is increasing.